USING THE COMFORT KIT (AVAILABLE SEPERATELY) 

 

The

 optional Comfort Kit allows the air conditioner to be used in 

spaces where there is not enough space to fit a standard 
portable air conditioner.    It allows the Airflex 15 to be placed 
outside the room to cool.    The air conditioner can then cool or 
heat the space via the Comfort Kit which acts also as a wired 
remote and a remote extender for the original remote.    By 
moving the unit outside the room the noise of the portable unit is 
significantly decreased. 
 
The Comfort Kit is available from your original retailer and 
manufacturer under stock code: 

AIRFLEX15V2-Comfortkit 

 
CONNECTING THE COMFORT KIT 

 

1.  Remove  the  blanking  plate  from  the  side  of  the  air 

conditioner by removing the two screws holding it in place. 
 

2.  Attach the comfort kit in position in the room, ensuring there 

is  space  behind,  to  allow  both  the  vent  pipe  and 
communication wire to be routed to the Airflex 15. 

 
 

3.  Attach  the  wire  from  Comfort  Kit  to 

the side of the air conditioner.    This 
both  provides  power  to  the  Comfort 
Kit,  and  communicates  when  the 
remote or buttons on the Comfort Kit 
are used. 

 
 

4.  Attach one end of the exhaust hose onto the 

back  of  the  comfort  kit  by  twisting  it  into 
position.    The  opposite  end  of  the  hose 
should then be attached to the Hot air outlet 
on the air conditioner for heating, or the Cold 
air outlet for cooling. 
 

 
Your Comfort Kit is now ready to use.    Both the 
remote supplied with the air conditioner, and the 
buttons on the Comfort Kit can be used to control 
the operation of the air conditioner. 
 
Note: We would advise for the unit to be situated 
indoors  when  using  the  heating  function,  to 
ensure efficient performance of the unit.

Содержание AIRFLEX15-V2

Страница 1: ...TPUMP AIRFLEX15 V2 Thank you for choosing electriQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference Visit our page www electriQ co uk for...

Страница 2: ...RUCTIONS 3 FEATURES AND PARTS LIST 5 INSTALLATION 6 CONTROL PANEL AND SETTINGS 9 OPERATION MODE 13 USING THE COMFORT KIT AVAILABLE SEPERATELY 17 DUAL DUCTING THE UNIT 18 WATER DRAINAGE 19 MAINTENANCE...

Страница 3: ...nsible for their safety Do not leave children unsupervised with this appliance Do not clean the unit by spraying it or immersing it in water Never connect the unit to an electrical outlet using an ext...

Страница 4: ...ly qualified engineer Before opening and servicing the unit the authorized engineer must be in possession of a copy of the manufacturer s service manual and must follow the safety information containe...

Страница 5: ...nk needed Compact robust design Digital Control Panel with IP 24 splash proof protection Bright LED screen indicates desired temperature and error codes Remote control and 24 hours start stop timer th...

Страница 6: ...ease note that it must always be kept upright and then placed on an even surface UNPACKING YOUR NEW AIR CONDITIONER Open the box and remove the outer carton by sliding it upwards from the base Grip th...

Страница 7: ...rage 2 Insert the hose and rotate it firmly into the adapter 3 To remove the hose twist it in the opposite direction Note To install the hose for heat mode please remove the hose the hose connector an...

Страница 8: ...lide bar on most windows and doors but without sealing the rest of the window opening the efficiency of the unit will be reduced Ensure that the opening left is as small as possible The best form of i...

Страница 9: ...he temperature set fault codes diagnostic and protective codes 1 Standby Button 9 Heating Indicator 2 Temp Button 10 IR Remote Sensor 3 Function Button 11 High Fan Speed Indicator 4 Timer Button 12 Me...

Страница 10: ...e set time has elapsed the unit will turn on automatically 3 Press the POWER button before the time has elapsed and the unit will turn on as normal and the timer will be cancelled 4 The function and f...

Страница 11: ...CO will be shown in the display dependant on model The LED display is also used to show error codes should a fault occur E1 The room temperature sensor is open or of short circuit E4 Water is full nee...

Страница 12: ...N A in dehumidification mode Temp Increase desired temperature in 1 degree increments Temp Decrease desired temperature in 1 degree increments Mode Change between Heating Cooling Dehumidifying fan an...

Страница 13: ...set it to a comfortable 20 22 C in cooling mode The electriQ Airflex 15 is a self evaporating air conditioner so under normal use there is usually no need to empty the internal tank However if there...

Страница 14: ...ll expel hot air Place the unit in the shade if possible and in a cool protected place in order to increase efficiency and to avoid overheating At an ambient temperature of over 32 C the unit will sto...

Страница 15: ...mp is 7 C 23 C when placed indoors It will work if the outside temperature is less than 7 C but the indoor temperature should be higher than 7 C You may want to quickly heat the room to above 10 C wit...

Страница 16: ...tching on the compressor will only start after a 3 minute delay For full heating effect please allow a further 10 minutes of operation Using the Airflex Comfort Kit will enable wired or wireless contr...

Страница 17: ...wo screws holding it in place 2 Attach the comfort kit in position in the room ensuring there is space behind to allow both the vent pipe and communication wire to be routed to the Airflex 15 3 Attach...

Страница 18: ...ir outside with the unit inside to increase performance This is perfect for classroom environments or similar where during summer the unit can be kept in a store room ducting cold air into the classro...

Страница 19: ...g Remove the water plug and attach a drain pipe running to the water container water will drain from the internal container Put the water plug back securely CONTINUOUS DRAINAGE Remove the water plug C...

Страница 20: ...arm about 40 C water with a neutral detergent d Rinse it and then dry it thoroughly e Carefully re install the air filter END OF SEASON MAINTENANCE 1 Pull out the plug from the drainage hole and empty...

Страница 21: ...unit on a flat surface Carpet is best for reducing vibrations from the compressor Compressor does not work Overheating protection is active Check the vent is straight and un restricted Restart the uni...

Страница 22: ...ositing your equipment Please contact the local council for details of your local household waste recycling centres TECHNICAL DATA MODEL Airflex15 V2 Capacity Cooling 4000 W Heating 3200 W Rated Input...

Страница 23: ...refrigerant gas as there could be a danger of fire or explosion hazard should the refrigerant come into contact with electric heaters stoves or other sources of ignition electriQ UK SUPPORT www electr...

Отзывы: