ElectrIQ AIRFLEX15-V2 Скачать руководство пользователя страница 11

 
 

Page 

11

  of 

23

 

 

(7)  to (9) FUNCTION INDICATORS 

An LED will illuminate to show which mode the unit is currently in.    This can be changed 
between Dehumidify (7), Cooling (8) and Heating (9) using the Function Button (3) 

 
(10) IR REMOTE SENSOR 

Receives infra red signals from the supplied remote control 

 
(11) to (14) FAN SPEED INDICATORS 

An  LED  will  illuminate  to  show  which  fan  speed  the  unit  is  currently  set  to.    This  can  be 
changed  between  High  (11),  Medium  (12),  Auto  (13)  and  Low(14)  using  the  fan  speed 
button (6). 

 

(15) LED

 

DISPLAY

   

Shows  the  set  temperature  or  timer  settings  while  in  normal  operation.  When  the  set 
temperature or the timer is adjusted, the new setting is shown on the display. 
 

  When  the 

TEMP+ 

or 

TEMP-

  buttons  are  pressed,  the  display  will  show  the  desired 

temperature currently set. 

  When the 

[TIMER]

 button is pressed the number of hours remaining will be shown until 

function is achieved or deactivated.   

 

In the dehumidification function, “dH” or “CO” will be shown in the display (dependant on 
model).   

 
The LED display is also used to show error codes should a fault occur 
 

  E1 

The  room  temperature  sensor  is  open  or  of  short 
circuit. 

E4 

Water is full, need manual drainage 

 

MULTI PROTECTIVE FUNCTION 

 

ANTI-FREEZE PROTECTION CONTROL: 

When  the  ambient  temperature  is  low  while  in  Cooling  Mode,  the  compressor  and  water 
pump  will  stop  working  if  the  copper  coil  temperature  is  too  low.  When  the  copper  coil 
temperature increases, the protection will be stopped automatically. 

While in this mode “Df” 

will be displayed on the unit. 

 

WATER-FULL PROTECTION: 

When  the  water  level  in  the  internal  water  tank  is  above  the  maximum  level,  the  unit  will 
alert automatically and E4 will be displayed on the LED screen. Please discharge the water 
from the water tank by following the instructions in the 

“Water Drainage” section. 

 

COMPRESSOR PROTECTION 

The  compressor  has  overheat  protection  which  may  stop  the  compressor  to  prevent 
damage. The compressor also has a 3 minute delay protection function which delays the 
start of the compressor, to help protect the compressor against repeated loss of power.   
 

Содержание AIRFLEX15-V2

Страница 1: ...TPUMP AIRFLEX15 V2 Thank you for choosing electriQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference Visit our page www electriQ co uk for...

Страница 2: ...RUCTIONS 3 FEATURES AND PARTS LIST 5 INSTALLATION 6 CONTROL PANEL AND SETTINGS 9 OPERATION MODE 13 USING THE COMFORT KIT AVAILABLE SEPERATELY 17 DUAL DUCTING THE UNIT 18 WATER DRAINAGE 19 MAINTENANCE...

Страница 3: ...nsible for their safety Do not leave children unsupervised with this appliance Do not clean the unit by spraying it or immersing it in water Never connect the unit to an electrical outlet using an ext...

Страница 4: ...ly qualified engineer Before opening and servicing the unit the authorized engineer must be in possession of a copy of the manufacturer s service manual and must follow the safety information containe...

Страница 5: ...nk needed Compact robust design Digital Control Panel with IP 24 splash proof protection Bright LED screen indicates desired temperature and error codes Remote control and 24 hours start stop timer th...

Страница 6: ...ease note that it must always be kept upright and then placed on an even surface UNPACKING YOUR NEW AIR CONDITIONER Open the box and remove the outer carton by sliding it upwards from the base Grip th...

Страница 7: ...rage 2 Insert the hose and rotate it firmly into the adapter 3 To remove the hose twist it in the opposite direction Note To install the hose for heat mode please remove the hose the hose connector an...

Страница 8: ...lide bar on most windows and doors but without sealing the rest of the window opening the efficiency of the unit will be reduced Ensure that the opening left is as small as possible The best form of i...

Страница 9: ...he temperature set fault codes diagnostic and protective codes 1 Standby Button 9 Heating Indicator 2 Temp Button 10 IR Remote Sensor 3 Function Button 11 High Fan Speed Indicator 4 Timer Button 12 Me...

Страница 10: ...e set time has elapsed the unit will turn on automatically 3 Press the POWER button before the time has elapsed and the unit will turn on as normal and the timer will be cancelled 4 The function and f...

Страница 11: ...CO will be shown in the display dependant on model The LED display is also used to show error codes should a fault occur E1 The room temperature sensor is open or of short circuit E4 Water is full nee...

Страница 12: ...N A in dehumidification mode Temp Increase desired temperature in 1 degree increments Temp Decrease desired temperature in 1 degree increments Mode Change between Heating Cooling Dehumidifying fan an...

Страница 13: ...set it to a comfortable 20 22 C in cooling mode The electriQ Airflex 15 is a self evaporating air conditioner so under normal use there is usually no need to empty the internal tank However if there...

Страница 14: ...ll expel hot air Place the unit in the shade if possible and in a cool protected place in order to increase efficiency and to avoid overheating At an ambient temperature of over 32 C the unit will sto...

Страница 15: ...mp is 7 C 23 C when placed indoors It will work if the outside temperature is less than 7 C but the indoor temperature should be higher than 7 C You may want to quickly heat the room to above 10 C wit...

Страница 16: ...tching on the compressor will only start after a 3 minute delay For full heating effect please allow a further 10 minutes of operation Using the Airflex Comfort Kit will enable wired or wireless contr...

Страница 17: ...wo screws holding it in place 2 Attach the comfort kit in position in the room ensuring there is space behind to allow both the vent pipe and communication wire to be routed to the Airflex 15 3 Attach...

Страница 18: ...ir outside with the unit inside to increase performance This is perfect for classroom environments or similar where during summer the unit can be kept in a store room ducting cold air into the classro...

Страница 19: ...g Remove the water plug and attach a drain pipe running to the water container water will drain from the internal container Put the water plug back securely CONTINUOUS DRAINAGE Remove the water plug C...

Страница 20: ...arm about 40 C water with a neutral detergent d Rinse it and then dry it thoroughly e Carefully re install the air filter END OF SEASON MAINTENANCE 1 Pull out the plug from the drainage hole and empty...

Страница 21: ...unit on a flat surface Carpet is best for reducing vibrations from the compressor Compressor does not work Overheating protection is active Check the vent is straight and un restricted Restart the uni...

Страница 22: ...ositing your equipment Please contact the local council for details of your local household waste recycling centres TECHNICAL DATA MODEL Airflex15 V2 Capacity Cooling 4000 W Heating 3200 W Rated Input...

Страница 23: ...refrigerant gas as there could be a danger of fire or explosion hazard should the refrigerant come into contact with electric heaters stoves or other sources of ignition electriQ UK SUPPORT www electr...

Отзывы: