TROUBLESHOOTING 

 

Do not repair or disassemble the air conditioning. Unqualified repair will invalidate the warranty and may lead to failure, 
causing injuries and property damage. Only use it as directed in this user manual and only perform operations advised here. 
 

Problems 

 

Reasons 

 

Solutions 

 

The air 
conditioner does 
not work.  

There is no electricity.  

Turn it on after connecting it to a socket with 
electricity.   

The display shows "E7".

 

 

Discharge the water inside.  

The ambient temperature is too low or 
too high  

Only use to use the machine within temperature 
range of 7-35

C

 (44-95

F

).  

In cooling mode, the room temperature is 
lower than the desired temperature 

Change the desired temperature.  

In dry mode, the ambient temperature is 
low.

 

 

The ambient temperature must be above 17 

C

.  

(62 

F

).  

The cooling  
effect is not good 

There is direct sunlight.  

Use curtains to reduce the direct sun heat  

Doors or windows are open; there are a 
lot of people; or in cooling mode, there 
are other sources of heat (e.g. fridges)   

Close doors and windows; increase air 
conditioning power  

The filter screen is dirty.  

Clean or replace the filter screen.  

The air inlet or outlet is blocked.  

Clear obstructions; make sure venting is correct as 
described in this user manual and hose is not bent   

Loud Noise  

The air conditioning is not placed on a flat 
surface.   

Put the air conditioning on a flat and hard place 
(to reduce noise).  

Compressor does 
not work.  

Overheat protection starts.  

Wait for 3 minutes until the temperature is 
lowered, and then restart the machine.  

The remote 
control does not 
work.  

The distance between the machine and 
the remote control is too far.  

Let the remote control get close to the air 
conditioner, and make sure that the remote 
control directly faces the receiver.  

The remote control is not aligned with 
the receiver.  

Batteries are dead.  

Replace batteries.  

Others  

No refrigerant or there is very little 
refrigerant  

Refer to Service Centre (check leakage, wielding, 
vacuum pump, charge refrigerant according to 
name plate)  

Anti-freezing protection  

Waiting for defrosting.  
Function will recover automatically. No user input 
needed.  

High pressure protection      

After  inside  gas  pressure  comes  down,  it  will 

function normally. No user input needed  

If problems not listed in the table occur or recommended solutions do not work, please contact the 

service centre.  

 
ERROR CODES  

CODE

 

CAUSE

 

SOLUTION 

dH 

Unit in dry mode 

Not a fault, no action required. 

E4

 

Room temperature sensor error

 

Check to ensure filters are clean, vent pipe is not 
restricted, and room temperature is within operational 
range. 

E2

 

Coil temperature sensor error

 

E7

 

Water full alarm

 

Empty the water tank  

MODE 

LIGHT 

FLASHING

 

Cool / dry / heating mode, the 
compressor has not started, the mode 
light will flash. This is normal

 

The unit will start operation when the protection 
period has finished ( approx. 3 minutes) 

 

 

Содержание 1535026

Страница 1: ...ECOSILENT8WE ECOSILENT10W 10 000 BTU ECOSILENT10WE Thank you for choosing electriQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference Visi...

Страница 2: ...REMOTE CONTROL 9 WIFI APP CONTROL 10 SETTING UP THE APP 10 CONNECTING THE AIR CONDITIONER 12 CONTROLLING YOUR DEVICE 14 SMART SCENES 17 CLEANING AND MAINTENANCE 20 EMPTYING THE INTERNAL WATER TANK 21...

Страница 3: ...th this appliance Do not clean the unit by spraying it or immersing it in water Never connect the unit to an electrical outlet using an extension cord If an outlet is not available one should be insta...

Страница 4: ...ised the refrigerant system Any repairs or maintenance must only be carried out on the unit by a suitably qualified engineer Before opening and servicing the unit the authorised engineer must be in po...

Страница 5: ...oved Energy Efficiency 24 Hours Start Stop Timer Digital Thermostat Smart WIFI App control Castors and Handles for Enhanced Portability Auto Restart to retain the settings in the event of power failur...

Страница 6: ...t outlet on the rear of the appliance by putting into position and twisting to lock in place 3 Make sure the unit is upright and there are no obstructions to the air inlets and outlet grills INSTALLAT...

Страница 7: ...our air conditioner should be used without the vent pipe in dry mode When using dry mode ensure that an external water tank is used monitored and regularly emptied before overflowing Permanent plumbin...

Страница 8: ...cannot be changed in SMARTCOOL and DRY modes Press to enter sleep mode The sleep indicator will be illumined and all other indicators will be turned off In sleep mode the appliance works at low fan s...

Страница 9: ...ll enter auto defrost and the heating symbol will flash on the control panel AUTOMATIC THERMAL PROTECTION To protect the service life of the machine the machine has automatic thermal protection If the...

Страница 10: ...OR SETUP The air conditioner has two different setup modes EZ Quick Connection and AP Access Point The quick connection is a quick and simple way to set the unit up The AP connection uses a direct loc...

Страница 11: ...mail address or phone number and press continue to register 4 A verification code will be sent by the method selected in step 3 Enter the code into the app 6 The app is now registered It will automati...

Страница 12: ...p 2 Select the type of device as Air Conditioner WIFI within the Large Home Appliance tab 3 Select your network enter your WIFI password and press Next 4 Ensure the WIFI light on the air conditioner i...

Страница 13: ...Ensure the WIFI light on the air conditioner is slowly flashing once per three seconds then select AP Mode in the top right corner before pressing on the orange button at the bottom of the screen to...

Страница 14: ...Allows you to program intelligent behaviour based on the internal and external environment Add Device Add a device to the app and go through the setup process Profile Provides the option for changing...

Страница 15: ...desired temperature Current Room Temperature Displays the current room temperature Back Returns to the Home Screen Desired Temperature Shows what temperature the unit is currently set to MODE Change t...

Страница 16: ...g the ADD ANOTHER ROOM option at the bottom See ADD ANOTHER ROOM below 5 Untick any rooms that are not required on the app 6 Press DONE in the top right corner SETTING YOUR LOCATION ADD ANOTHER ROOM U...

Страница 17: ...ing the user to easily change between a number of preset configurations Below is an example of how to set up a scene 1 Press on the Smart Scene tab at the bottom of the Home screen 3 Select the type o...

Страница 18: ...o add a smart scene 3 Select the type of automation required such as on schedule for setting up a timed operation 5 Chose the function set the value for the function and then press the back button in...

Страница 19: ...ROUBLESHOOTING 1 Check whether the device is powered on and is in the correct WIFI connection mode if not please refer to the CHANGING BETWEEN CONNECTION MODES section on page 12 2 Ensure the WIFI pas...

Страница 20: ...d once every two weeks or as often as necessarily in your environment CLEAN THE UPPER FILTER SCREEN FRAME Grip the edge of the evaporator filter screen frame with both hands Pull out to remove the fil...

Страница 21: ...ter tank in cooling mode If the unit is vented correctly most of the water is reused to cool the condenser coils and any excess is evaporated Please do not use continuous drainage if you intend to use...

Страница 22: ...ce Put the air conditioning on a flat and hard place to reduce noise Compressor does not work Overheat protection starts Wait for 3 minutes until the temperature is lowered and then restart the machin...

Страница 23: ...triQ co uk support Please for your own convenience make these simple checks before calling the service line If the unit still fails to operate call the number below or complete the online form 0330 39...

Страница 24: ...nt R290 280g R290 220g Sound power level 61dB A Thermostat 17 30oC Maximum working pressure of suction exhaust side 1 0 3 5MPa Maximum Allowable Pressure 3 5Mpa Power Supply AC 220 240V 50Hz Net Weigh...

Отзывы: