ElectrIQ 1535026 Скачать руководство пользователя страница 21

21 

 

EMPTYING THE INTERNAL WATER TANK 

 

 
MANUAL DRAINAGE:

 

When the internal water tank is full the unit will stop working, and the unit will display 
E7.

 

Turn off the unit and unplug. Try not to move the model abruptly as this may cause 
the water in the internal tank to spill out.

 

Place a tray under the lower water plug or place the unit in a drainage area.

 

Unscrew the drain plug cap and remove the rubber stopper - water will drain from the 
internal tank. Put the rubber stopper back and screw the drain plug cap back into place.

 

 
 

CONTINUOUS DRAINAGE:

 

Unscrew the drain plug cap and remove the rubber stopper.

 

Connect a water pipe to the upper water outlet.

 

You can plumb this pipe into your current plumbing system, lead it outside and 
use gravity fall or use a water pump.

 

 
 

 
 
NOTE: 

This model has a self-evaporative function, which reduces the need to empty the water tank in cooling 

mode. If the unit is vented correctly most of the water is reused to cool the condenser coils and any excess 
is evaporated. Please do not use continuous drainage if you intend to use the self-evaporating facility.

 

 
 

END OF SEASON MAINTENANCE  

1.

 

Remove the rubber stopper from the drainage hole and empty the internal tank. You can also 
drain the water by leaning the unit backwards.

 

2.

 

Run the unit in fan mode, with a low fan speed, with the rubber stopper still removed, and a 
container under the drain port.

 

3.

 

Keep the unit in this mode for half day - until the conduit is dried. Doing this helps to keep the 
inside of the unit dry and prevents mould from developing.

 

4.

 

Turn off the unit and pull out the plug.

 

5.

 

Replace the rubber stopper.

 

6.

 

Coil the wire and bind it together, then put it into the accessory space.

 

7.

 

Separate the vent pipe and store it safely.

 

8.

 

Cover the unit and keep it in a dry place.

 

9.

 

Take  the  batteries  out  of  remote  control  and  store  or  dispose  of  them  safely.  Keep  all 
accessories with the unit ready for next season.

 

 

 

 

Содержание 1535026

Страница 1: ...ECOSILENT8WE ECOSILENT10W 10 000 BTU ECOSILENT10WE Thank you for choosing electriQ Please read this user manual before using this innovative Air Conditioner and keep it safe for future reference Visi...

Страница 2: ...REMOTE CONTROL 9 WIFI APP CONTROL 10 SETTING UP THE APP 10 CONNECTING THE AIR CONDITIONER 12 CONTROLLING YOUR DEVICE 14 SMART SCENES 17 CLEANING AND MAINTENANCE 20 EMPTYING THE INTERNAL WATER TANK 21...

Страница 3: ...th this appliance Do not clean the unit by spraying it or immersing it in water Never connect the unit to an electrical outlet using an extension cord If an outlet is not available one should be insta...

Страница 4: ...ised the refrigerant system Any repairs or maintenance must only be carried out on the unit by a suitably qualified engineer Before opening and servicing the unit the authorised engineer must be in po...

Страница 5: ...oved Energy Efficiency 24 Hours Start Stop Timer Digital Thermostat Smart WIFI App control Castors and Handles for Enhanced Portability Auto Restart to retain the settings in the event of power failur...

Страница 6: ...t outlet on the rear of the appliance by putting into position and twisting to lock in place 3 Make sure the unit is upright and there are no obstructions to the air inlets and outlet grills INSTALLAT...

Страница 7: ...our air conditioner should be used without the vent pipe in dry mode When using dry mode ensure that an external water tank is used monitored and regularly emptied before overflowing Permanent plumbin...

Страница 8: ...cannot be changed in SMARTCOOL and DRY modes Press to enter sleep mode The sleep indicator will be illumined and all other indicators will be turned off In sleep mode the appliance works at low fan s...

Страница 9: ...ll enter auto defrost and the heating symbol will flash on the control panel AUTOMATIC THERMAL PROTECTION To protect the service life of the machine the machine has automatic thermal protection If the...

Страница 10: ...OR SETUP The air conditioner has two different setup modes EZ Quick Connection and AP Access Point The quick connection is a quick and simple way to set the unit up The AP connection uses a direct loc...

Страница 11: ...mail address or phone number and press continue to register 4 A verification code will be sent by the method selected in step 3 Enter the code into the app 6 The app is now registered It will automati...

Страница 12: ...p 2 Select the type of device as Air Conditioner WIFI within the Large Home Appliance tab 3 Select your network enter your WIFI password and press Next 4 Ensure the WIFI light on the air conditioner i...

Страница 13: ...Ensure the WIFI light on the air conditioner is slowly flashing once per three seconds then select AP Mode in the top right corner before pressing on the orange button at the bottom of the screen to...

Страница 14: ...Allows you to program intelligent behaviour based on the internal and external environment Add Device Add a device to the app and go through the setup process Profile Provides the option for changing...

Страница 15: ...desired temperature Current Room Temperature Displays the current room temperature Back Returns to the Home Screen Desired Temperature Shows what temperature the unit is currently set to MODE Change t...

Страница 16: ...g the ADD ANOTHER ROOM option at the bottom See ADD ANOTHER ROOM below 5 Untick any rooms that are not required on the app 6 Press DONE in the top right corner SETTING YOUR LOCATION ADD ANOTHER ROOM U...

Страница 17: ...ing the user to easily change between a number of preset configurations Below is an example of how to set up a scene 1 Press on the Smart Scene tab at the bottom of the Home screen 3 Select the type o...

Страница 18: ...o add a smart scene 3 Select the type of automation required such as on schedule for setting up a timed operation 5 Chose the function set the value for the function and then press the back button in...

Страница 19: ...ROUBLESHOOTING 1 Check whether the device is powered on and is in the correct WIFI connection mode if not please refer to the CHANGING BETWEEN CONNECTION MODES section on page 12 2 Ensure the WIFI pas...

Страница 20: ...d once every two weeks or as often as necessarily in your environment CLEAN THE UPPER FILTER SCREEN FRAME Grip the edge of the evaporator filter screen frame with both hands Pull out to remove the fil...

Страница 21: ...ter tank in cooling mode If the unit is vented correctly most of the water is reused to cool the condenser coils and any excess is evaporated Please do not use continuous drainage if you intend to use...

Страница 22: ...ce Put the air conditioning on a flat and hard place to reduce noise Compressor does not work Overheat protection starts Wait for 3 minutes until the temperature is lowered and then restart the machin...

Страница 23: ...triQ co uk support Please for your own convenience make these simple checks before calling the service line If the unit still fails to operate call the number below or complete the online form 0330 39...

Страница 24: ...nt R290 280g R290 220g Sound power level 61dB A Thermostat 17 30oC Maximum working pressure of suction exhaust side 1 0 3 5MPa Maximum Allowable Pressure 3 5Mpa Power Supply AC 220 240V 50Hz Net Weigh...

Отзывы: