background image

INSTALLATION GUIDE

READINGS

READINGS DISPLAYED IN THE UPPER SCREEN AREA
(The parameters available vary according to instrument confi guration)

Ea

Er

Es

U

U-f

I

P

Q

S

PF

Ea Imp

Er Ind 

Imp

Es Imp

L-N

L-N

f

I

P

Q

S

PF

Press to scroll readings

Ea Exp

Er Cap 

Imp

Es Exp

L-L

L-L

f

In

P Avg 

Imp

Q Avg 

Imp

S Avg 

Imp

Ea 

Phase

Er Ind 

Exp

THD 

L-N

THD L-N

f

THD

P Avg 

Exp

Q Avg 

Exp

S Avg 

Exp

Er Cap 

Exp

THD L-L THD L-L

f

I Max

P MD 

Imp

Q MD 

Imp

S MD 

Imp

Er Ind 

Phase

Min L-N Min L-N

I Avg

P MD 

Exp

Q MD 

Exp

S MD 

Exp

Min L-L Min L-L

I MD

Max L-N Max L-N

Max L-L Max L-L

READINGS DISPLAYED IN THE LOWER SCREEN AREA
(The parameters available vary according to instrument confi guration)

Press to change readings

Press for 2 seconds

Ea ∑+

Er L ∑+

Er C ∑+

Es ∑+

Ea ∑-

Er L ∑-

Er C ∑-

Es ∑-

Ea P+

Er L P+

Er C P+

Es P+

Ea P-

Er L P-

Er C P-

Es P-

CNT1 ∑
CNT1 P
TIME ∑

TIME P

TEMP °C

TEMP °F

LEGEND OF PARAMETERS AND SYMBOLS

L-N

Phase Neutral

U

Voltage

L-L

Phase Phase

I

Current

THD

Total Harmonic Distortion

In

Neutral current

Avg

Average (rolling) value

P

Active Power

MD

Maximum Demand

Q

Reactive Power

Imp (+)

Import value

S

Apparent Power

Exp (-)

Export value

PF

Power Factor

IND

Inductive

Ea

Active Energy

CAP

Capacitive

Er

Reactive Energy

Min

Minimum values (10 cycles time base)

Es

Apparent Energy

Max

Maximum values (10 cycles time base) f

Frequency

TIME ∑

Life Time (total)

TEMP °C

Temperature in °Celsius

TIME P

Life Time (partial)

TEMP °F

Temperature in °Fahrenheit

CNT ∑

Pulse count (total)

CNT P

Pulse count (partial)

!

FEMTO D4

Keep pressed for 2 
seconds to display:
- Type of instrument
- Firmware version
- Serial number
- RS485 address

MECHANICAL CHARACTERISTICS

Case

Self-extinguishing plastic material class V0

Protection degree

IP40 on front panel

Size

70 x 90 x 58 mm (4 DIN modules)

CURRENT INPUT

Direct

Up to 300 Vrms phase-neutral
or 519 Vrms phase to phase

With external PT(VT)

Primary: programmable (max. 400 kV)
Secondary: programmable (max. 300 V)
Overload: 900 Vrms phase to phase for 1 sec

Power supply

230//- 10% 50/60Hz

Self consumption

< 3VA

MODELS

PFA6411-02

FEMTO D4 RS485 230-240V 
ENERGY ANALYZER

PFA6411-12

FEMTO D4 RS485 230-240V 1DI 2DO 
ENERGY ANALYZER

COPYRIGHT

Electrex is a trademark of Akse S.r.l. All rights reserved.
It is forbidden to duplicate, adapt, transcript this document without Akse written authorization, 
except when regulated accordingly by the Copyright Laws.

WARRANTY 

This product is covered by a warranty against material and manufacturing defects for a 24 
months period from the manufacturing date.
The warranty does not cover the defects that are due to: 
• Negligent and improper use  
• Failures caused by atmospheric hazards 
• Acts of vandalism 
• Wear out of materials
• Firmware upgrades
Akse reserves the right, at its discretion, to repair or substitute the faulty products   
The warranty is not applicable to the products that will result defective in consequence of a 
negligent and improper use or an operating procedure not contemplated in this manual. 

RETURN AND REPAIR FORMALITIES

  

Akse accepts the return of instruments for repair only when authorized in advance. The 
transport costs are at customer charge. 

RE-SHIPPING OF REPAIRED PRODUCT

  

The terms for re-shipment of repaired products are ex-works, i.e. the transport costs are 
at customer charge.
Products returned as detective but found to be perfectly working by our laboratories, will 
be charged a fl at fee to account for checking and testing time irrespective of the warranty 
terms.

SAFETY

 

This instrument was manufactured and tested in compliance with CEI EN 61010-1 CAT 
III -300V, class 2, standards  for operating voltages up to 300 VAC rms phase to neutral. 
In order to maintain this condition and to ensure safe operation, the user must comply with 
the indications and markings contained in the following instructions: 

• When the instrument is received, before starting its installation, check that it is 

intact and no damage occurred during transport. 

•  Before  mounting,  ensure  that  the  instrument  operating  voltages  and  the  mains 

voltage are compatible then proceed with the installation. 

• The instrument power supply needs no earth connection. 
•  The  instrument  is  not  equipped  with  a  power  supply  fuse;  a  suitable  external 

protection fuse must be foreseen by the contractor. 

•  Maintenance  and/or  repair  must  be  carried  out  only  by  qualifi ed,  authorized 

personnel 

• If there is ever the suspicion that safe operation is no longer possible, the instrument 

must be taken out of service and precautions taken against its accidental use. 

• Operation is no longer safe when:

1) There is clearly visible damage. 
2) The instrument no longer functions. 
3) After lengthy storage in unfavorable conditions. 
4) After serious damage occurred during transport

The instruments must be installed in respect of all the local regulations.

OPERATOR SAFETY

Warning:

  Failure  to  observe  the  following  instructions  may  lead  to  a  serious  danger  of 

death.

• During normal operation dangerous voltages can occur on instrument terminals and 

on  voltage  and  current  transformers.  Energized  voltage  and  current  transformers 
may generate lethal voltages. Follow carefully the standard safety precautions while 
carrying out any installation or service operation.

• The terminals of the instrument must not be accessible by the user after the installation. 

The  user  should  only  be  allowed  to  access  the  instrument  front  panel  where  the 
display is located.

• Do not use the digital outputs for protection functions nor for power limitation functions. 

The instrument is suitable only for secondary protection functions.

• The instrument must be protected by a breaking device capable of interrupting both 

the power supply and the measurement terminals. It must be easily reachable by the 
operator and well identifi ed as instrument cut-off device.

• The instrument and its connections must be carefully protected against short-circuit.

Precautions:

 Failure to respect the following instructions may irreversibly damage to the 

instrument.

• The outputs and the options operate at low voltage level; they cannot be powered by 

any unspecifi ed external voltage.

• The application of currents not compatible with the current inputs levels will damage 

to the instrument.

Further documentation may be downloaded from our web site www.electrex.it.

This document is owned by company AKSE that reserves all rights. 

DECLARATION OF CONFORMITY

 

Akse hereby declares that its range of products complies with the following directives EMC 
89/336/EEC   73/23CE   93/68 CE   and complies with the following product’s standard CEI 
CEI EN 61326 – IEC 61326   CEI EN 61010 – IEC 61010 
The  product  has  been  tested  in  the  typical  wiring  confi guration  and  with  peripherals 
conforming to the EMC directive and the LV directive.

Содержание Femto D4

Страница 1: ...ts returned as detective but found to be perfectly working by our laboratories will be charged a flat fee to account for checking and testing time irrespective of the warranty terms SAFETY This instrument was manufactured and tested in compliance with CEI EN 61010 1 CAT III 300V class 2 standards for operating voltages up to 300 VAC rms phase to neutral In order to maintain this condition and to en...

Страница 2: ...uency of U1N f Hz 220 Phase to Neutral Voltage RMS Amplitude U1N V 222 Phase to Neutral Voltage RMS Amplitude U2N V 224 Phase to Neutral Voltage RMS Amplitude U3N V 226 Phase to Phase Voltage RMS Amplitude U12 V 228 Phase to Phase Voltage RMS Amplitude U23 V 230 Phase to Phase Voltage RMS Amplitude U31 V 232 Phase Current RMS Amplitude I1 A 234 Phase Current RMS Amplitude I2 A 236 Phase Current RM...

Страница 3: ...HRE Alarm threshold in absolute value with the exception made for DERIV and UNBAL in which the value inserted becomes a percentage Note n 6 AVG Parameter to be used only in DERIV mode Is the duration of the refe rence in seconds used to create a reference value for the istantaneous readings Note n 7 NORMAL Physical output of the alarm excited during the duration of the alarm It restores automatica...

Страница 4: ...cted Disregard of this warning or of wiring diagram leads to major measurement errors VOLTAGE AND CURRENT CONNECTION S1 S2 S1 S2 S1 S2 A B T 10 11 12 17 18 19 20 U1 U2 U3 N I1 I2 I3 RS 485 AUX AUX VOLTAGE INPUT POWER L N FUSE 50mA T 230 240 V 10 Serial RS485 port A B T Subject to modification without notice Edition 2015 04 24 ENG0055 STAR 4W 4 WIRES 3PH 4W SINGLE PHASE 1PH 2W BI PHASE 2PH 2W TRIANG...

Отзывы: