GENERAL SPECIFICATIONS
Maximum Voltage between any Terminal and Earth Ground: 250V
Measurement rate: updates 2-3/sec.
Over range indication: “1” figure only in the display
Automatic negative polarity indication.
The “ ” is displayed when the battery voltage drops below the operating voltage.
Operating temperature: 10°C~40°C, 0~75% R.H.
Storage temperature: -10°C~50°C, 0~75% R.H.
Power: 2 X 1.5V AAA battery
Dimensions: 126L*70W*24Hmm.
Weight: approx 140g (including battery)
FRONT PANEL DESCRIPTION
)81&7,21$1'5$1*(6:,7&+
This switch is used to select the function and desired
range as well as to turn on the instrument. To extend the life of this battery, the switch should be in the
«OFF» position when the instrument is not in use.
',63/$<
3 1/2 digits, 7 segment, 12,50mm high LCD.
©&RPPRQª-$&.
Plug in connector for black (negative) test lead.
©9ȍP$ª-$&.
Plug in connector for red (Positive) test lead for all voltage and resistance and
current (except 10A) measurements.
5. «10A» JACK Plug in connector for red (Positive) test lead for 10A measurement
• When using the probes, keep your fingers behind the finger guards on the probes.
• Connect the common test lead before you connect the live test lead. When you disconnect
test leads, disconnect the live test lead first.
• Remove the test leads from the meter before you open the battery door.
• Do not operate the meter with the battery door or portions of the cover removed or loosened.
• To avoid false readings, which could lead to possible electric shock or personal injury, replace
the batteries as soon as the low battery indicator (“
”) appears.
• Safety Compliance: EN61010-1, 2000 CAT III 250V over voltage standards. Do not measure
voltages above 250V in Category II installations..
Over voltage installation categories per EN61010-1, 2000: The Meter is designed to protect
against transients in these categories:
CAT I From high-voltage low-energy sources, e.g., electronic circuits or a copy machine.
CAT II From equipment supplied from the fixed installation, e.g., TVs, PCs, portable tools and
household appliances.
CAT III From equipment in fixed equipment installations, e.g., installation panels, feeders and
short branch circuits, and lighting systems in large buildings.