Universale Quick User Guide Rev.1.10 ENG Delectrais an Elettrolab Group brand
10
7.3 MEASURE menu
The MEASURE menu allows access to key parameter measurements of the device such as for instance, internal temperature,
LED temperature, POH counter (total power on hours, to measure device life), etc. For more details please refer to the
schematic below:
MEAS
TEMP
T.LED
It shows the temperature detected by the external NTC (10KΩ) on the LED module. Power
derating above 85°C.
T.BOR
It shows the internal device temperature. Power derating above 85°C.
DMIN
CH1 / CH..
0
255
It shows the DMX level of the input channels.
RATE
It shows the DMX rate of the input signal.
ALRM
It shows the error messages.
LED
It shows the output percentage level.
FRE
It shows the internal PWM frequency.
I.OUT
It shows the output current setting.
HOUR
UNIT
It shows the unit life time.
LIFE
It shows the LEDs life time.
LIF.R
It shows the LEDs life time: this value is resettable.
S.VER