7
Outlet joint
Tubing joint
Hook-
panel
Water-
receiver
Swing Motor
Hook-
bolt
cross-
screwdriver
Chart 11
body
ceiling
panel sponge
panel
panel foam 1
air out
outlet foam
fan
bukpeshku i
panelit 2
Chart 12
Chart 13
leakage
ceiling
pollution
water condensation
Gap not allowed
Loosen
upper nut
Adjust
lower nut
Chart 14
Installation
cover’s rope
Tap screw
Chart 15
Slide the four
sliders in the
corresponding
channel when
installing the
cover.
(3)Install the panel
a. Align the swing motor on the panel to the tubing joints of the body properly. (Refer to chart 11)
b. Fix hooks of the panel at swing motor and its opposite sides to the hooks of corresponding water
receiver. (Refer to chart 11
①
) Then hang the other two panel hooks onto corresponding hangers of
the body. (Refer to chart 11
➁
)
CAUTION
c. Adjust the four panel hook screws to keep the panel horizontal, and screw them up to the ceiling
evenly. (Refer to chart 11
➂
)
d. Regulate the panel in the direction of the arrow in Chart 11
➃
slightly to fit the panel’s center to the
center of the ceiling’s opening. Guarantee that hooks of four corners are fixed well.
e. Keep fastening the screws under the panel hooks, until the thickness of the sponge between the body
and the panel’s outlet has been reduced to about 4~6mm. The edge of the panel should contact with
the ceiling well. (Refer to chart 12)
•
Malfunction described in Chart 13 can be caused by inappropriate tightness the screw.
•
If the gap between the panel and ceiling still exists after fastening the screws, the height of the indoor
unit should be modified again. (Refer to chart 14-left)
•
You can modify the height of the indoor unit through the openings on the panel’s four corners, if the
lift of the indoor unit and the drainpipe is not influenced. (Refer to chart 14-right)
(4)Hang the air-in grid to the panel, then connect the lead terminator of the swing motor and that
of the control box with corresponding terminators on the body respectively.
(5)Relocate the air-in grid in the procedure of reversed order.
(6)Relocate the installation cover.
a. Fasten the rope of installation cover on the bolt of the installation cover. (Refer to chart 15-left)
b. Press the installation cover into the panel slightly. (Refer to chart 15-right)
Do not coil the wiring of the swing motor into the seal sponge.
SZ000289/En
06/23/2004, 2:39 PM
19
Содержание KN 24 RC
Страница 16: ...4 2 OUTLINE DIMENSIONS Revision Y06 02 Service Manual KN Series 4 2 Outdoor Unit OU7 24 4 3 Outdoor Unit OU8 30...
Страница 17: ...4 3 OUTLINE DIMENSIONS Revision Y06 02 Service Manual KN Series 4 4 Outdoor Unit OU10 36 OU10 47...
Страница 50: ...9 2 REFRIGERATION DIAGRAMS Revision Y06 02 Service Manual KN Series 9 1 2 KN 30 R410A...
Страница 51: ...9 3 REFRIGERATION DIAGRAMS Revision Y06 02 Service Manual KN Series 9 1 3 KN 36 R410A...
Страница 52: ...9 4 REFRIGERATION DIAGRAMS Revision Y06 02 Service Manual KN Series 9 1 4 KN 36T R410A...
Страница 53: ...9 5 REFRIGERATION DIAGRAMS Revision Y06 02 Service Manual KN Series 9 1 5 KN 45T R410A...
Страница 57: ...11 2 CONTROL SYSTEM Revision Y06 02 Service Manual KN Series 11 1 3 Main PCB Controller...
Страница 100: ...13 7 EXPLODED VIEWS AND SPARE PARTS LISTS Revision Y06 02 Service Manual KN Series 13 7 Outdoor Unit OU7 24 RC 1PH...
Страница 104: ...13 11 EXPLODED VIEWS AND SPARE PARTS LISTS Revision Y06 02 Service Manual KN Series 13 11 Outdoor Unit OU7 24 RC 3PH...
Страница 108: ...13 15 EXPLODED VIEWS AND SPARE PARTS LISTS Revision Y06 02 Service Manual KN Series 13 15 Outdoor Unit OU8 30 RC 1PH...
Страница 111: ...13 18 EXPLODED VIEWS AND SPARE PARTS LISTS Revision Y06 02 Service Manual KN Series 13 18 Outdoor Unit OU8 30 ST 1PH...
Страница 114: ...13 21 EXPLODED VIEWS AND SPARE PARTS LISTS Revision Y06 02 Service Manual KN Series 13 21 Outdoor Unit OU8 30 RC 3PH...
Страница 116: ...13 23 EXPLODED VIEWS AND SPARE PARTS LISTS Revision Y06 02 Service Manual KN Series 13 23 Outdoor Unit OU8 30 ST 3PH...
Страница 118: ...13 25 EXPLODED VIEWS AND SPARE PARTS LISTS Revision Y06 02 Service Manual KN Series 13 25 Outdoor Unit OU10 36 RC 1PH...
Страница 120: ...13 27 EXPLODED VIEWS AND SPARE PARTS LISTS Revision Y06 02 Service Manual KN Series 13 27 Outdoor Unit OU10 36 ST 3PH...
Страница 122: ...13 29 EXPLODED VIEWS AND SPARE PARTS LISTS Revision Y06 02 Service Manual KN Series 13 29 Outdoor Unit OU10 36 RC 3PH...
Страница 124: ...13 31 EXPLODED VIEWS AND SPARE PARTS LISTS Revision Y06 02 Service Manual KN Series 13 31 Outdoor Unit OU10 36 ST 3PH...
Страница 126: ...13 33 EXPLODED VIEWS AND SPARE PARTS LISTS Revision Y06 02 Service Manual KN Series 13 33 Outdoor Unit OU10 47 RC 3PH...
Страница 128: ...13 35 EXPLODED VIEWS AND SPARE PARTS LISTS Revision Y06 02 Service Manual KN Series 13 35 Outdoor Unit OU10 47 ST 3PH...
Страница 132: ...14 3 OPTIONAL ACCESSORIES Revision Y06 02 Service Manual KN Series 14 3 RCW RCW2 Wiring Connections as Shown on Kit...