11-6
CONTROL SYSTEM
Revision Y05-02
Service Manual - Delta DCI
11.7.2
Indoor Coil over Heating Protection
ICT
ICT Trend
Fast
Decreasing
Decreasing
No Change
Increasing
Fast
Increasing
ICT > 55
SC
SC
SC
SC
SC
53 < ICT ≤ 55
D1
D1
D2
D2
D2
49 < ICT ≤ 53
SR
SR
D1
D2
D2
47 < ICT ≤ 49
SR
SR
SR
D1
D2
45 < ICT ≤ 47
Norm
Norm
SR
SR
D1
43 < ICT ≤ 45
Norm
Norm
Norm
SR
SR
ICT ≤ 43
Normal
11.7.3
Compressor over Heating Protection
Compressor temperature can be in one of 5 control zones (4 in protection, and 1 normal),
according to the following chart.
Control Status
Compressor Temperature
Increases
Else
P1
Norm
SR
P2
D1
SR
P3
D2
D1
Stop Compressor
SC
Normal
P1
P2
Stop-Compresor
CTTOH1
CTTOH2
CTTOH3
CTTOH4
CTT
P3