To select a mode press the / buttons until the desired mode is
displayed then press the OK button to select that mode.
Operation:
When the unit is powered on the UV lamp is switched on, the UV lamp will
switch off under the following conditions ie:
•
Dosing pump ‘On’ (and for 30 minutes after the dosing pump has
completed dosing)
•
No or low water flow (the UV lamp(s) cannot be switched on unless
the unit is receiving sufficient flow) See page 10 for flow requirements.
UV Lamp Life:
Adjust Dose
The digital controller has three modes ie:
•
UV LAMP LIFE
•
DOSAGE
•
TIMER
Whenever the UV lamp is ‘On’ a timer
counts down from 9,000 hours and
the remaining UV lamp life is dis-
played.
From 9,000 hours to 500 hours the
LED in the control panel will light in
green. When 499 hours is reached
the LED colour will change to amber,
when 0 hours are reached the LED
light will change to red indicating
that the lamp(s) must be changed.
UV Life 460 Hrs
Dose 40m/d
LED Indicator
Fig 13.