background image

F

ULL

 I

NSTALLATION

 I

NSTRUCTIONS

 

Screw mount the Pool-Smart to a wall in a dry weather proof location, ensuring that it is sited no 
more than 3 metres from the swimming pool filtration pipe work and upstream i.e. before the 
heating appliance.  
Solvent cement the PVC T-Piece into the pipe work ensuring the direction arrow (moulded into 
the T-Piece) is pointing in the direction of flow. 
Electrical connection: - 
To access the internal terminal connection block  
Remove the 4 cover screws in the lower section of the controller housing & connect as follows: 
 
Terminal 1 and 2 Power supply 100-230 volt ac mains  
Terminal 3 and 4 connect to the filtration pump / contactor controlling the filtration pump 

(volt 

free switched output 2-Amp MAX)

 

Terminal 5 and 6 connect to the heating appliance (volt free switched output) 
Terminal 7 and 8 connect to the flow switch in the T-Piece  
Terminal 9 and 10 connect to the temperature sensor in the T-Piece  
For programming and functionality refer to the digital controller key section  

Q

UICK

 S

ET

-U

P

 G

UIDE

 

P

OSITIONING

 

The Pool-Smart should be installed in a dry weather proof location that will allow access to the 
control buttons. Consideration must be given to the positioning of the T-Piece to ensure both the 
controller and T-Piece are no more than 3 metres apart. 
The T-Piece incorporates a flow switch and temperature sensor and must be sited up stream,  
i.e. before, the pool heating appliance.  

T-P

IECE

 I

NSTALLATION

 

W

ALL

 M

OUNTING

 

The rear face of the Pool-Smart has an upper key hole screw hook, located at the rear of the en-
closure, and 2 lower screw holes which are accessed after removing the 4 screws retaining the 
lower access cover. 

The T-Piece should be cut into the swimming pool filtration pipe work up stream (i.e. before) the 
heating appliance using a suitable PVC cement. The T-Piece has slip fit female 63-mm and is 
supplied with 50-mm reducers for metric countries or 1½" reducers for imperial countries. 
Note:- correct orientation of the T-Piece is essential in order to facilitate the correct operation of 
the flow switch, and temperature detecting probe i.e. the arrow moulded into the T-Piece must 
point in the direction of flow. 

Содержание Pool-Smart

Страница 1: ...THIS CONTROL DEVICE MUST BE INSTALLED BY A QUALIFIED ELECTRICIAN Do Not Discard Keep For Future Reference Incorrect Installation Will Affect Your Warranty Pool Smart Installation Instructions Operatin...

Страница 2: ...tal controller key section QUICK SET UP GUIDE POSITIONING The Pool Smart should be installed in a dry weather proof location that will allow access to the control buttons Consideration must be given t...

Страница 3: ...ces should terminals 5 and 6 be connected to a load greater than 2 Amp Recommended connection method Using a suitable 2 core wire connect the 2 cores from one end of the wire to terminals 5 and 6 Then...

Страница 4: ...ivate Priority of Heating The actual pool temperature is displayed in the red upper display The lower green display required temperature can be selected by the user This is the temperature you would l...

Страница 5: ...d off switching cycling the Pool Smart digital controller has been pre programmed with a time delay function This prevents rapid fluctuations in temperature or flow volume from switch ing the heating...

Страница 6: ...NT This product complies with EU directive 2002 96 EC Do Not dispose of this product as unsorted municipal waste This symbol on the product or on it s packaging indicates that this product should not...

Страница 7: ...rmonised standards have been applied EN 60335 2 35 Elecro Engineering Limited Unit 11 Gunnels Wood Park Stevenage Hertfordshire SG1 2BH UK Tel 44 0 1438 749 474 Fax 44 0 1438 361 329 Website www elecr...

Отзывы: