2.  GENERAL INSTALLATION INSTRUCTION 

 

2.1 Mounting instruction

 

 

The  heater  should  be  either  installed  horizontally  or  vertically  allowing  enough  space  for  the  pipe 
connections and wiring.  It should be firmly secured using screws to a firm base or wall.  
 

WARNINGS: 

If the heater is placed against a combustible material a fireproof barrier must be 
placed  between  the  unit  and  the  wall,  this  must  cover  a  minimum  of  15cm 
around the outside of the heater. The unit must not be covered to allow adequate 
ventilation. 

 

 

 

The heater must be installed within a dry, permanent weather-proof area. In any 
case where water or moisture enters the enclosure the warranty will be void. 

 

Caution:

 

If the heater is unused during the winter months, it 

must be

 drained to prevent 

frost damage. Water 

must not

 be allowed to freeze in the heater, as this will 

cause severe damage. 

 

2.2 Pipework 

 
The heater should be installed at a low point in the filtration system. It should be positioned downstream 
of (after) the filter and upstream of (before) any dosing or other water treatment plan. (see Fig. 2). 

 

 

Fig. 2 

 

 
 
 
 

Содержание Nano SPA Heater

Страница 1: ...Nano SPA Heater Installation Operating Manual...

Страница 2: ...ion 4 2 2 Pipework 4 2 3 Flow direction 6 2 4 Electrical connection 6 2 5 Power requirements 7 3 OPERATING INSTRUCTIONS 7 3 1 Flow requirements 7 3 2 Water quality 7 4 TROUBLESHOOTING 8 5 MAINTENANCE...

Страница 3: ...of trouble free service please read and follow these instructions for proper installation maintenance and use Incorrect installation will affect the warranty WARNING Failure to install the unit correc...

Страница 4: ...of the heater The unit must not be covered to allow adequate ventilation The heater must be installed within a dry permanent weather proof area In any case where water or moisture enters the enclosur...

Страница 5: ...letely full of water during operation the return pipe which carries the water back to the pool must incorporate a safety loop or kick up in the pipe as close as possible to the heater see Fig 3 NOTE W...

Страница 6: ...ecause of the ridges in the pipe it will not squeeze down tight It will need to be sealed with a bathroom type mastic sealant 2 3 Flow direction The heater can accept the flow of water from only one e...

Страница 7: ...ax 4 5 mg litre Total Dissolved Solids TDS Calcium hardness 200 1 000 ppm The permitted salt concentration is dependent on the model of heater purchased Incoloy 825 heating element Zero salt content p...

Страница 8: ...the test i e with the heater red light On To avoid inaccurate results when performing this test it is important to refrain from using other high current consuming appliances in the property such as tu...

Страница 9: ...ble Check both ends of the power supply cable at the distribution box and at the heater terminal block Remedy Contact an Electrician to check installation and protection Heater is tripping circuit bre...

Страница 10: ...ocess 5 MAINTENANCE We recommend annual maintenance and cleaning of the heater to ensure proper operation WARNING Before performing any maintenance on the unit isolate from the main power supply The h...

Страница 11: ...Proof of purchase may be required The manufacturer will not be liable in cases of incorrect installation of the heater inappropriate use or neglect of the heater Any damages occurred due to shipping m...

Страница 12: ...12 8 WIRING DIAGRAMS Nano SPA 1 2 and 3 kW Nano SPA 4 5 and 6 kW Nano SPA 8 kW...

Страница 13: ...Hertfordshire SG1 2BH United Kingdom __________________________________________________________________________________ Customer Information ATTACH TO HEATER Company Name Contact Name Daytime Telepho...

Страница 14: ...14...

Страница 15: ...15 Notes...

Страница 16: ...11 Gunnels Wood Park Stevenage Herts SG1 2BH Sales elecro co uk www elecro co uk 44 0 1438 749474 Copyright V01 2019...

Отзывы: