IMPORTANT NOTES 

 
Thank  you  for  purchasing  the  H.R.UV-C  SPA  pool  sanitising  system,  the  latest  in  high  reflection  UV 
technology, manufactured to the highest standards in England. 
 
To ensure years of trouble-free service, please read and follow these instructions for proper installation, 
maintenance and use. 

Incorrect installation will affect your warranty. 

 

Please retain this manual for future reference. 

 

1.  IMPORTANT SAFETY INSTRUCTIONS 

 

WARNINGS: 

  Read the maintenance instructions before opening the appliance. 

  Do not operate the ultraviolet-C emitter when it is removed from the appliance enclosure.  

  Unintended use of  the appliance or damage to the housing may result in the escape of 

dangerous ultraviolet-C radiation.  ultraviolet-C radiation may, even in  little doses,  cause 
harm to the eyes and skin.  

  This unit must be earthed.  

  Power must be supplied through a Residual Current Device (RCD) with a rated residual 

operating current not exceeding 30mA 

  Do not run this unit dry 

  Do not cover this unit 

  The unit must not be submerged in water 

  Carefully examine the unit after installation. It should not be powered on if there is water 

on any parts not intended to be wet 

  If the unit shows any sign of water leakage immediately disconnect power supply 

  If the quartz sleeve is cracked, replace it immediately 

  To avoid injuries young children should never be allowed near UV steriliser 

  Failure  to  disconnect  the  power  from  the  UV  steriliser  and  pump  before  servicing  or 

maintenance could result in personal injury or property damage. 
 
 

2.  PRODUCT OVERVIEW 

 

 
The 

H.R.UV-C SPA 

is available in 30W single tube format.           

             

 

 

 

Содержание H.R.UV-C SPA-STANDARD

Страница 1: ...H R UV C SPA STANDARD Installation Operating Manual HR 30 B SPA ENGLISH...

Страница 2: ...work 5 3 3 Flow direction 6 3 4 Connection 7 3 6 Electrical connection 8 4 OPERATING INSTRUCTIONS 9 4 1 Flow requirements 9 4 2 Water quality 9 5 MAINTENANCE 9 5 1 Essential parts to carry out annual...

Страница 3: ...olet C radiation ultraviolet C radiation may even in little doses cause harm to the eyes and skin This unit must be earthed Power must be supplied through a Residual Current Device RCD with a rated re...

Страница 4: ...4 Fig 1 Dimensions Fig 2...

Страница 5: ...alling vertically the 1m clearance space must be above or below the unit if installing horizontally the 1m clearance space must be to the left or right of the unit WARNING The device must be installed...

Страница 6: ...6 Fig 4 3 3 Flow direction The device is factory set to accept input water flow entering on the left and exiting on the right...

Страница 7: ...unit is supplied with unions to allow connection to 2 or 63 mm rigid pipe Reducers are also supplied to allow connection to 50 mm or 1 rigid pipe see Fig 7 For pipework 63 mm or 2 in diameter For pipe...

Страница 8: ...lation may result in serious damage to property persons The device must be installed in accordance with the country regional requirements and regulations and an Electrical Installation Certificate mus...

Страница 9: ...al Dissolved Solids TDS Calcium hardness 200 1 000 ppm WARNING Failure to meet the water quality limits will void the warranty Upon completion of the installation run the water circulating pump to pur...

Страница 10: ...lamp and quartz sleeve Unscrew all the highlighted fasteners Unclamping the clip from body 1 Pull the clip in shown direction to unlock from body 2 Pull the second side after unlocking the 1st side R...

Страница 11: ...leeve can be removed Slide the O ring off the quartz sleeve The quartz sleeve can now be removed Cleaning the quartz sleeve Clean the sleeve and polish with a soft cloth or paper towel If you live in...

Страница 12: ...ttings have been manufactured from polymers that have been specifically stabilised to protect them from the effects of the UVC emitted from the UV lamps Despite this UV protection they will be eroded...

Страница 13: ...y for inspection Proof of purchase may be required The manufacturer will not be liable in cases of incorrect installation of the product inappropriate use or neglect Any damages occurred due to shippi...

Страница 14: ...14 Notes...

Страница 15: ...ertfordshire SG1 2BH United Kingdom __________________________________________________________________________________ Customer Information ATTACH TO THE PRODUCT Company Name Contact Name Daytime Tele...

Страница 16: ...16 Unit 11 Gunnels Wood Park Stevenage Herts SG1 2BH Sales elecro co uk www elecro co uk 44 0 1438 749474 Copyright MANE321 EN H R UV C SPA STANDARD Manual V1 01 09 2021 Elecro...