background image

Created: May 2018 (1st Edition)

Instruction Manual

HCT-BTP01 series

ECLEAR LEANUP

For use in Japan only.

A customer who purchases outside Japan should refer to the 

localized manuals in the country of purchase.

www.elecom.co.jp/global/download-list/manual/

Thank you for purchasing Eclear leanup. 
This Instruction Manual features operating methods, as well as precautions for safe handling of 
the product. 
Be sure to read this Instruction Manual prior to using the product. Store this Instruction Manual 
for safekeeping once you have finished reading.

Содержание Eclear LEANUP

Страница 1: ...manuals in the country of purchase www elecom co jp global download list manual Thank you for purchasing Eclear leanup This Instruction Manual features operating methods as well as precautions for saf...

Страница 2: ...press When unconnected to the main unit the pairing settings interface is displayed Due to continuous version upgrades specifications are subject to change without notice 2 This product is an EMS prod...

Страница 3: ...less security 9 Package contents 10 Names of individual components 11 Preparation Charging 12 Attaching the gel pad 14 Use Basic operations 16 Using the dedicated app ECLEAR APP 18 Examples for applyi...

Страница 4: ...e can be stimulated What is relaxation frequency The relaxation frequency is a low frequency in the range of 20 to 30 Hz By relaxing the muscles contracted by the deep layer frequency you can train fo...

Страница 5: ...al equipment Internally implanted electronic devices such as pacemakers Electrical life support devices such as arti cial hearts and lungs Wearable medical electrical devices such as an ECG If used wi...

Страница 6: ...ur doctor before using the product if any of the following conditions apply You are undergoing treatment or suffering a health condition Malignant cancer Heart or cranial nerve abnormalities Your temp...

Страница 7: ...on the same day Do not use it for more than 30 minutes It may cause accidents or discomfort Ensure the main unit and gel pad are connected correctly and securely before use Do not use it on more than...

Страница 8: ...pad with wet hands Otherwise an electric shock malfunction or accident may occur Do not use a special USB cable when it is damaged or when the USB connector insertion receptacle is loose Otherwise a...

Страница 9: ...s that require a license specific low power radio stations that require no license and amateur radio stations WARNING Do not use this product on a machine that may have significant adverse effects due...

Страница 10: ...ite Gray Core pad 1 consumable Accessories Sold Separately Inquire the retailer for details on separately sold accessories The following items are sold separately Accessory Instruction Manual 1 Storag...

Страница 11: ...ctive film Gel Pad Main Unit Gel pad Dedicated USB Cable USB A port USB micro B connector When using the core pad 11 Front side Back side Power button switch mode button Convex Strong button USB port...

Страница 12: ...C are continuously lit A B C and D are all continuously lit B blinks A is continuously lit C blinks A and B are continuously lit USB connector slot PC AC adapter for charging Dedicated USB cable USB m...

Страница 13: ...at up or start a fire The product cannot be operated while charging Certain mobile power supplies may not be suitable for charging After repeated charging of the main unit the time a full charge lasts...

Страница 14: ...rom the gel pad yet Make sure that the main unit is powered off LED indicator is off Connect the gel pad terminal to the main unit until you hear a click Connect the gel pad terminal to the main unit...

Страница 15: ...top of metal such as a necklace or navel piercing Do not apply gel pads on tattoos CAUTION 15 Attaching the gel pad 3 Attach the gel pads to the desired body parts Attach the gel pad onto the skin sec...

Страница 16: ...the mode changes A B C D A It makes a long beep sound when it returns to mode A 2 Adjusting the training level 3 You can choose the desired intensity from fifteen levels When connecting to the power s...

Страница 17: ...t the same time two beeps will sound indicating that all sound has been muted For security reasons sound is generated for certain operations even in mute mode This is not a fault If you accidentally m...

Страница 18: ...played Click Download Android version The Google Play download page is displayed 18 Please use the dedicated ECLEAR APP to activate and use the product Although this product can be used separately you...

Страница 19: ...P On a smartphone with the dedicated ECLEAR APP installed pair the smartphone with the product using Bluetooth For details refer to the smartphone user manual Paring phone and product 1 Choose Setting...

Страница 20: ...app ECLEAR APP Continued 20 Blinks in the sequence of A B C D A Power button Starting the dedicated ECLEAR APP 2 Pair the product with a smartphone 3 Tap the icon When the power button is pressed the...

Страница 21: ...t power supply When the pairing settings page is displayed follow the prompts on the page to pair the product with the smartphone or laptop Follow the prompts on the page for the product to automatica...

Страница 22: ...the gel pad is removed from the skin or the main unit the power turns off automatically To disconnect the product during a workout via the app use the button s on the product To change the connected...

Страница 23: ...thigh calf CAUTION Do not use it on more than two locations at the same time Half of the thickness when you pinch the arm with your elbow bent at 90 degrees Half of the thickness when you pinch your a...

Страница 24: ...ectly on to your skin Examples for applying gel pads Continued 24 Rectus abdominis core pad Abdominal oblique twin pad Adductor muscles twin pad Quadriceps femoris core pad Tibialis anterior twin pad...

Страница 25: ...use 25 Triceps brachii twin pad Latissimus dorsi core pad Gluteus maximus core pad Biceps femoris core pad Triceps surae twin pad Gluteus medius core pad Core pad Twin pad Back...

Страница 26: ...d off before peeling the gel pad from your skin Do not touch the adhesive surface of the gel pad Instead hold onto the knob to peel it off Do not disconnect the gel pad from the main unit Attach it to...

Страница 27: ...aintenance replace the gel pad Main unit maintenance Wipe dirt off the main unit with a soft cloth CAUTION Do not let water get into the main unit or USB port After use 27 Run a small amount of water...

Страница 28: ...ons Storage temperature 10 C to 60 C Storage humidity 20 85 RH Maintenance and storage precautions Do not use benzene or thinner to service the product Do not store the product in the locations descri...

Страница 29: ...st that you recycle them Lithium ion batteries are precious resources that can be recycled so we request that you recycle them Precautions for disposing of lithium ion batteries Do not disassemble the...

Страница 30: ...pply Short press the button during use P 16 The main unit and gel pad are not connected correctly Disconnect the power and then reconnect the main unit and gel pad P 14 Power disconnected during use B...

Страница 31: ...veral seconds P 27 The gel pad is not properly connected Connect it correctly by pushing it in until it clicks P 14 The adhesive surface of the gel pad is dirty or damaged Gel pads are consumables Whe...

Страница 32: ...hone P 9 The product cannot be operated via a smartphone Before pairing press the button on the product Before pairing press the button on the product to start a workout without pairing In this case y...

Страница 33: ...1 Charge time Approx 2 5 hours 3 Operating time Over 90 minutes fully charged 4 Rated output voltage Approx 42 V Deep layer frequency Approx 2000 5000 Hz Relaxation frequency Approx 20 30 Hz Timer Ap...

Страница 34: ...rk Google Google trademark Google Play Google Play trademark Google LLC trademark or registered trademark Apple Apple trademark iPad iPhone are trademarks of Apple Inc registered in the U S and other...

Отзывы: