background image

HEAT PUMP SYSTEMS WITH ADDITIONAL

WATER HEATERS (HEAT PUMP SYSTEMS)

OF 120 and 150 l.

DESIGNED FOR WALL

MOUNTING

SPECIFICATIONS

INSTALLATION, USE AND MAINTENANCE INSTRUCTIONS

IMPORTANT RULES

WARNING!

 

Before installing and operating the water heater read carefully the instructions!

1

Содержание HPS120

Страница 1: ...HEATERS HEAT PUMP SYSTEMS OF 120 and 150 l DESIGNED FOR WALL MOUNTING SPECIFICATIONS INSTALLATION USE AND MAINTENANCE INSTRUCTIONS IMPORTANT RULES WARNING Before installing and operating the water he...

Страница 2: ...using the appliance there is a risk of hot water scalding especially when the water in the water heater is heated to temperatures closer the thermostat higher limit WARNING This appliance is not inte...

Страница 3: ...or body consisting of water heater with heat exchanger condenser Both units are connected with pipes through which flows refrigerant Within the external unit package you shall find the stand for appli...

Страница 4: ...re inserted anodes of special alloy which during its wear provide additional protection of the enamel lining The water used for heating must comply with legislation in force for household water qualit...

Страница 5: ...It is necessary as well that the floor in the premise be equipped with trap for wastewater as it is possible during normal operation from the relief valve outlet from time to time to drip water The wa...

Страница 6: ...most suitable position with enough space on the wall in order to make easier the installation and maintenance of the outdoor unit Fig 1 b The outdoor unit is installed on support or curtain wall with...

Страница 7: ...s for the refrigerant must be thermally insulated in order to prevent burns cuts or loss of product The pipes should not be wet and dirty Avoid any sharp bends of pipes or harm to its cylindrical shap...

Страница 8: ...on the pipes f Place the pipes brass nuts in the right direction and make cones on pipe s both ends in suitable shape and size with appropriate tool Fig 6 Grease Fig 6 g Connect the two pipes with in...

Страница 9: ......

Страница 10: ...and let it run It shall make vacuum for about 20 25 minutes d Check whether the pressure gauge indicates pressure equal to 1 bar or 76 cm Hg e Close the pump valve Make sure that the pressure gauge a...

Страница 11: ...re necessary i e with water supply network pressure over 0 6 MPa 1 3 2 5 6 4 Hot water Cold water Cold water To mixing tab The water heater is fit with combined check safety valve mounted on the cold...

Страница 12: ...eat pump operated water heater is provided with electricity protection Class Water heater power supply takes place through separate circuit of three wire cable with 2 5 mm2 section of each wire phase...

Страница 13: ...the electric circuit schema on Fig 13 by connecting the phase conductor to the terminal marked L the neutral conductor to terminal marked N and the earthling conductor to the terminal marked for earth...

Страница 14: ...e input terminals of the appliance must not be interrupted by other circuit breaker or fuse If the appliance in installed in a bathroom the disconnecting unit must be located out of the premise Follow...

Страница 15: ...ion of the outdoor unit communication cable to the column terminal on the indoor unit electric circuit marked R G shall be carried out by connecting the three wires to the terminals respecting colour...

Страница 16: ...ut zero Then connect the UPS exit to terminals Lin phase and Nin zero WARNING It is imperative to connect properly the UPS outlet cable to the unit terminal i e to comply with phase and zero When remo...

Страница 17: ...ty grounding Following the connection and fixing of power cables to the electronic unit place the plastic covers of the indoor and outdoor units on their locations and screw them carefully to leave in...

Страница 18: ...supplies the electric heater and the circulating pump All modes of electronic control function normally No power supply In this case there is no power to the electric heater Only the electronic contr...

Страница 19: ...SPLAYING INFORMATION The appliance electronic control panel offers some options for modes of operation These modes provide for different capacities for the unit These modes are as follow Standby Auto...

Страница 20: ...ows for three sub modes heating only by the heat pump combined heating with the heat pump and the electric heater and heating only with the electric heater The first sub mode HP allows heating only wi...

Страница 21: ...temperature in this case is 55 combined operation ending at 45 and then additional heating only by the heat pump In all modes of operation the field Measured or set parameters provides useful informat...

Страница 22: ...C frozen water High I current protection is active High Press heat pump high pressure protection is active L Fail unsuccessful legionella protection cycle Long Defr too long defrosting process Freq D...

Страница 23: ...settings shall be ignored SCREEN MENUS IN SETTINGS MODE Change of temperature set When the water heater is switched on then pressing one of the buttons or shall allow passage to change the temperatur...

Страница 24: ...ion Switches on and off the automatic legionella protection Switching on the legionella protection initiates legionella cycle immediately after return to initial condition if the water heater is switc...

Страница 25: ......

Страница 26: ...ING INFORMATION The appliance electronic control panel offers some options for modes of operation These modes provide for different capacities for the unit These modes are as follow Standby Auto Timer...

Страница 27: ...heating only with the heat pump The maximum water heating temperature in this mode is 55 The second sub mode HP EL allows for combined heating with heat pump and electric heater with priority to the...

Страница 28: ...the display right side Initial time is displayed when the operation has still not begun while after beginning is displayed the end time Boost mode This mode is for rapid water heat and combines heatin...

Страница 29: ...ter The display sequence is as follow Temperature set Water heater bottom temperature Temperature before and after the outdoor defrost unit Date Anode protector state indicator Daytime rate consumed p...

Страница 30: ...collector overheat protection function shall not be activated Overheat2 the collector thermostat has registered temperature higher that the critical maximum values set Only the electric heating regime...

Страница 31: ...ed on then pressing one of the buttons or shall allow passage to change the temperature set Any further pressing of one of the buttons shall allow changing the temperature set in desired direction Pre...

Страница 32: ...itching on and time for switching off Legionella Protection Switches on and off the automatic legionella protection Switching on the legionella protection initiates legionella cycle immediately after...

Страница 33: ...plumbing The quantity of this water is negligible and usually is with low temperature During normal operation of the water heater as well as in present of additional return valve it is possible that...

Страница 34: ...because being violation of the present instruction for installation and operation 3 WARNING This appliance is not intended for use by persons including children with reduced physical sensory or mental...

Страница 35: ...operation do not forget to fill the water tank with water please refer to section Water heater connection to the water supply network WARNING When draining water all precaution for damages from outflo...

Страница 36: ...Producer ELDOMINVEST Ltd 9009 Varna 275A Boulevard Vladislav Varnenchik fax 359 52 500 347 Trade Department 359 52 502 109 Service Department 359 52 502 113 www eldominvest com mail eldominvest com 36...

Отзывы: