5.4.  Authentication

In this section the user can set up the details required for logging in to ELAN Configuration Web Server.

8

User name

 – User name required for authorization to log in to LAN MESSENGER web server. Default user name is 1234. 

Password for user 

– Password for authorization to log in to LAN MESSENGER web server. Default password is 1234. 

Retype password

 – Repeat the password for confirmation when changing it.

5.5.  Statistics

This section provides the information regarding the established TCP connections. 

9

Socket

 – Sequence number of the socket.

State

 – Socket state:

• 

CONNECT

 – Successfully connected to remote IP address.

• 

LISTEN

 – Ready for connection.

• 

CLOSED

 – Connection is closed.

Rem IP

 – Remote IP address the device is connected to.

Rem Port

 – Remote port number  the device is connected through.

Loc Port

 – Local port number of the device.

Timer

 – Connection uptime in seconds.

5.6.  Inputs

The following section is intended for input configuration.

10

Mode
• 

Digital 

– The device measures the input voltage resulting in input state (violated/restored) change in accordance with the Thresh-

old parameter and data message delivery to the destination IP address (-es).

• 

Off

 – Input disabled.

Type
• 

NO

 – Sets input type as normally-open. Connecting the circuit leads to input violation. Default parameter.

• 

NC 

– Sets input type as normally-closed. Disconnecting the circuit leads to input violation.

Threshold 

– Sets the voltage value (mV) for Digital input mode. The device considers the input violated/restored once this value is exceed-

ed. Value range is 

0... 10000

 mV. Default value is 

1800

 mV. It is NOT recommended to change the default value.

For more details on input wiring, please refer to general wiring diagram provided in 

2.3. Wiring Diagrams.

5.7.  Outputs

This section is intended for output C1 and C2 control.
The LAN MESSENGER device comes equipped with 2 open collector outputs C1 and C2 designed for electrical appliance connection. Nor-

mally, outputs can be used to open/close garage doors, activate lights, heating, watering and much more. When output turns ON, the LAN 

MESSENGER triggers any equipment or relay connected to it (see 

2.3. Wiring Diagrams

).

When input Z4 is in use, output C2 will not be available. In such case C2/Z4 terminal can not be used as open-collector output. In order to use 

C2/Z4 terminal as open-collector output, disable input Z4. For more details on input configuration, please refer to 

5.6. Inputs

NOTE:

  Output C2 and input Z4 DO NOT operate simultaneously.

11

The output can be turned ON or OFF by selecting a corresponding output status ON or OFF from the drop down list and clicking the 

Save

 

button afterwards. By default, output C1 and C2 are turned OFF.

Intelligent Security & Fire Ltd.

Содержание LAN MESSENGER

Страница 1: ...LAN MESSENGER ETHERNET AUTO DIALLER n t e l l i g e n t S e c u r i t y F i r e L t d...

Страница 2: ...any other linked device that the device is powered from A blown fuse cannot be replaced by the user The replacement fuse has to be of the kind indicated by the manufacturer Fuse F1 model miniSMDC 0 5...

Страница 3: ...made your purchase UAB ELDES CONTENTS OF PACK Item Quantity 1 LAN MESSENGER 1 2 User manual 1 3 Resistors 3 3k 4 4 Screws 2 Not included Power supply unit can be obtained from your local distributor E...

Страница 4: ...roller status F1 miniSMDC 0 5A fuse AC DC Power supply terminals C1 Open collector output terminal COM Common terminal C2 Z4 Open collector output digital input terminal Z3 Z2 Z1 Digital input termina...

Страница 5: ...ut or detection device connection such as magnetic door contact By connecting the device s input to the output of the equipment you will be able to receive a data message to the software regard ing eq...

Страница 6: ...on with EGR100 software Highly recommended for EGR100 data format Account ID 4 digit number required to identify the device by the monitoring station Default value is 9999 Unit ID 4 digit number requi...

Страница 7: ...y open Connecting the circuit leads to input violation Default parameter NC Sets input type as normally closed Disconnecting the circuit leads to input violation Threshold Sets the voltage value mV fo...

Страница 8: ...your local retail store where this product was purchased If your problem could not be fixed by the self guide above please contact your local distributor More up to date information about your device...

Страница 9: ...MadeintheEuropeanUnion www eldes lt n t e l l i g e n t S e c u r i t y F i r e L t d...

Отзывы: