Eldes GSM Axcess 2 Скачать руководство пользователя страница 6

Other functions

Delete a user

by sending the text

XXXX D:

, followed by the phone number

with country code, 46 for Sweden, and without initial zero.

l

XXXX, is replaced with the password.

l

For example,

1234 D.46701234567

, is sent to delete the Swedish

number

0701234567 from a system with

1234

as the password.

Delete all users

by sending the text

XXXX D: ALL

l

XXXX, is replaced with the password.

Find out the

signal strength

by sending XXXX INFO.

l

XXXX, is replaced with the password.

Change the

Relay time

by sending XXXX TIMER:xx.

l

XXXX, is replaced with the password.

l

xx, is replaced by the desired relay time.

LED description

SIM STAT

Off

SIM card is working

Red

SIM card error

NETW

Off

No reception

Flashes once every second

Poor reception

Flashes three times every second

Medium reception

Solid

Good reception

Factory reset

A factory reset removes the administrator numbers but not the user numbers.

Remove All under the tab Users Database and Clear Log under the tab Main Set-

tings must be performed manually in the PC software.

6 (7)

Quick guide GSM Axcess 2/3

Содержание GSM Axcess 2

Страница 1: ...ntrol AB Box 90215 120 23 Stockholm Sweden 08 722 34 40 info axema se www axema se GSM Axcess 2 3 ESIM 110 120 GSM Axcess is a remote controlled relay which activates using phone calls Quick guide Upd...

Страница 2: ...ess 2 3 ESIM 110 120 1 Introduction 3 Start Up 3 Configuration of GSM Axcess using the PC software 3 SMS configuration of GSM Axcess 4 Other functions 6 LED description 6 Factory reset 6 Technical Dat...

Страница 3: ...other obstructions 4 Supply voltage 10 24 V AC DC 5 GSM Axcess will start up after about one minute Start up is indicated by flashing of the NETW LED Configuration of GSM Axcess using the PC software...

Страница 4: ...show up now 12 Add delete or edit users l Add users by pressing Add and entering the phone number with country code 46 for Sweden and without initial zero Up to 500 users can be registered l Delete u...

Страница 5: ...r each administrator number l For example 1234 NR1 46701234567 is sent to add the first administrator with the Swedish number 0701234567 to a system with 1234 as the password 4 Add users by sending th...

Страница 6: ...XXXX INFO l XXXX is replaced with the password Change the Relay time by sending XXXX TIMER xx l XXXX is replaced with the password l xx is replaced by the desired relay time LED description SIM STAT...

Страница 7: ...jumper 3 Supply voltage for five second until the relay s click 4 Remove the voltage 5 Remove the jumper Technical Data Attributes GSM Axcess 2 3 Power Supply 10 24 V DC Maximum load relay 1 A 24 V IP...

Отзывы: