14
5.2.1 Voice Calls Method
ATTENTION:
DTMF phone number dialing mode must be enabled on alarm system, activated
Ademco Contact ID®
or
4+2
data
transmission protocol and monitoring station phone number set with international code, i.e. For UK London 20xxxxxxxx or
004420xxxxxxxx. The
plus
character is not allowed.
By this method the communicator receives
Ademco Contact ID®
or
4+2
protocol data sent from alarm system and transmits it to
monitoring station via GSM audio – direct channel.
NO jumpers have to be set on
SET/MODE
pins in order to select
Voice Calls
method. See Fig. No. 7.
If PSTN connection is used, the communicator also monitors the voltage (dial tone monitoring optional) on the PSTN and in case
the PSTN is unavailable, disconnected or cut off (voltage drops below 4V), ET082:
• switches to
Voice Calls
method,
• notifies monitoring station about PSTN failure,
• continues transmitting data to monitoring station via GSM audio – direct chanel until the PSTN is restored.
NOTE:
By default, notification about PSTN loss/restore is disabled and has to be enabled if required using
ELDES Configuration
Tool
software. For more details, please, refer to software’s HELP section.
5.2.2 SMS Method
ATTENTION:
It is necessary to set monitoring station phone number on alarm system for
SMS
method. In such case you can
use any number (one digit is enough).
By this method the communicator receives
Ademco Contact ID®
protocol data sent from alarm system and converts it to user-un-
derstandable text which is sent to preset user (-s) by SMS message.
1. Set the jumper on
MODE
pins in order to select
SMS
method. See Fig. No. 8.
2. Add user phone number (-s) to the communicator using
ELDES Configuration Tool
software.
3. Configure
Ademco Contact ID®
data message structure using
ELDES Configuration Tool
software if required.
For more details, please, refer to
ELDES Configuration Tool
software’s HELP section.
If PSTN connection is used, the communicator also monitors the voltage (dial tone monitoring optional) on the PSTN and in case
the PSTN is unavailable, disconnected or cut off (voltage drops below 4V), ET082:
• switches to
SMS
method,
• notifies the preset user (-s) by SMS message about PSTN failure,
• continues sending the converted
Ademco Contact ID®
by SMS message to preset user (-s) until the PSTN is restored.
NOTE:
By default, notification about PSTN loss/restore is disabled and has to be enabled if required using
ELDES Configuration
Tool
software. For more details, please, refer to software’s HELP section.