background image

GSM/GPRS COMMUNICATOR

ET082

Содержание ET082

Страница 1: ...GSM GPRS COMMUNICATOR ET082...

Страница 2: ...t be disconnected before any installation or tuning work starts The system installation or maintenance must not be done during stormy conditions The system must be powered by main 10 24V 300mA power s...

Страница 3: ...vice It is very impor tant to read the user manual before starting to use the system Contents 1 General Information 4 1 1 Operation Description 4 2 Technical Specifications 6 2 1 Electrical Mechanical...

Страница 4: ...channel Voice Calls GSM audio channel and or to users via SMS message GPRS network CSD fax line ET082 main applications features Property security Data re transmission to monitoring station via GSM GP...

Страница 5: ...or Input Output Control 3 Number of Low Level Negative Digital Inputs 3 Allowable Input Values Voltage 0 1 45V current 0 8 0 6mA Input Type NO normally open Number of Outputs 3 Output C1 C3 Circuit Ma...

Страница 6: ...ing factory default settings SET For communication method of Basic mode set up MODE For communication method of Basic mode set up JP8 JP9 For direct data transmission via PSTN with status monitoring U...

Страница 7: ...rs of ET082 and alarm system unit must be connected ET082 inputs Z1 Z3 are connected to PGM outputs of alarm system unit if PGM output is im plemented as open collector circuit or any other circuit an...

Страница 8: ...It is not recommended to turn on the device without GSM antenna connec ted NOTE It is recommended to install the GSM antenna away from the alarm system to ensure better quality of the audio signal It...

Страница 9: ...com Scancom Kronos Kronos Kronos Kronos EGR100 EGR100 EGR100 EGR100 SIA IP SIA IP SIA IP SIA IP Primary Voice Calls Voice Calls Voice Calls SMS SMS SMS GPRS 1 3 GPRS 1 3 GPRS 1 3 CSD CSD CSD N A N A B...

Страница 10: ...N or GSM is restored For more details please refer to ELDES Configuration Tool software s HELP section ET082 can also detect temporary service suspension by the service provider for technical or billi...

Страница 11: ...le text GPRS 1 destination IP address EGR100 Kronos SIA IP GPRS up to 3 destination IP addresses EGR100 Kronos SIA IP Voice Calls GSM audio direct channel SMS up to 5 users Ademco Contact ID by SMS co...

Страница 12: ...PSTN Connection With this wiring the communicator retransmits data from alarm system to monitoring station via landline PSTN 1 Connect the circuit as indicated in Fig No 5 connect telephone contacts o...

Страница 13: ...landline PSTN of PBX 4 Connect power supply to DC COM contacts Power supply is usually used as AUX and AUX output of alarm system 5 NO jumpers have to be set on JP8 JP9 pins 5 2 Basic Mode The communi...

Страница 14: ...ftware s HELP section 5 2 2 SMS Method ATTENTION It is necessary to set monitoring station phone number on alarm system for SMS method In such case you can use any number one digit is enough By this m...

Страница 15: ...on Tool software 3 Configure Ademco Contact ID data message structure using ELDES Configuration Tool software if required For more details please refer to ELDES Configuration Tool software s HELP sect...

Страница 16: ...vailable protocols Kronos Kronos LT Kronos NET monitoring station software data format EGR100 EGR100 GPRS software data format SIA IP SIA IP data format complying with ANSI SIA DC 09 2007 standard 3 S...

Страница 17: ...it to me mory buffer and transmits it to monitoring station via GSM audio channel Set the following ET082 parameters using ELDES Configuration Tool software 1 Switch to Advanced mode by enabling Backu...

Страница 18: ...Add user phone number s 5 Configure Ademco Contact ID data message structure if required For more details please refer to ELDES Configuration Tool software s HELP section If PSTN connection is used t...

Страница 19: ...ftware Port Forwarded TCP UDP port number for the computer running Kronos EGR100 software Protocol Format of the data message transmitted from ET082 to monitoring station by GPRS method Available pro...

Страница 20: ...p 1 and Backup 2 connections if required 4 Set CSD monitoring station phone number For more details please refer to ELDES Configuration Tool software s HELP section If PSTN connection is used the comm...

Страница 21: ...ameter and value For some parameters the value does not apply i e STATUS Software ELDES Configuration Tool is intended to work directly with ET082 system which can be connected to the computer via USB...

Страница 22: ...ost name and port number are saved in the device memory after the first successful connection 6 2 2 Connecting to ELDES Configuration Server using ELDES Configuration Tool Software 5 3 2 1 Run ELDES C...

Страница 23: ...S Example 1111_STATUS SMS text XXXX_ENDCONFIG Example 1111_ENDCONFIG The 4 digit SMS password intended for system configuration and control by SMS messages By default the SMS password is 0000 four zer...

Страница 24: ...nufacturer default input restore texts Z1 Input 1 RESTORED Z2 Input 2 RESTORED Z3 Input 3 RESTORED This command sets a restore text for a specified input Maximum allowed length is 23 charac ters inclu...

Страница 25: ...default output names C1 Output1 C2 Output2 C3 Output3 This command sets at name for a specified output Maximum allowed length is 23 characters Enable Input Set Output Name SMS text XXXX_Zx ON Value Z...

Страница 26: ...9999 Example 1111_C3 ON 75 SMS text XXXX_Cx OFF T or XXXX_OutputName OFF T Value T period of time in seconds range 1 9999 Example 1111_Pump OFF 50 The delay period of time between telephone line failu...

Страница 27: ...It is strongly recommended to restore parameters to default values after the firmware upgrade process 7 3 Technical Support Indication Possible Reason GSM LED is off or not flashing No external power...

Страница 28: ...28 8 Related products ET08P plastic enclosure Power supply...

Страница 29: ...User manual ELDES ET082 v1 2 29...

Страница 30: ...Made in Lithuania www eldes lt...

Отзывы: