Function
The RCL03/RCL04 Easywave mini receiver can
be operated in a voltage range of 12-24 V AC/DC.
2 potential-free relay outputs may be switched via
2 separate radio channels.
A total of 32 different Easywave radio transmis
-
sion codes can be memorized.
It is also possible to connect one external impulse
button for each channel which can then be used
to switch the corresponding relay according to the
selected operating mode.
Four operating modes are available:
-
DEAD MAN´S MODE
(factory setting)
-
ON/OFF
-
PULSE
-
ROLLER BLIND MOTOR CONTROL
for 2-button operation
-
ROLLER BLIND MOTOR CONTROL
for 3-button resp. 4-button operation
Operating Modes
The radio control can be operated in five differ
-
ent operating modes with Easywave transmitters
for 1-button-, 2-button-, 3-button operation. The
required operating mode can be selected with
jumper J1.
DEAD MAN´S MODE
(1-button operation)
Each relay can be switched separately. The re-
lay is triggered as long as the corresponding
transmitter button or the corresponding external
impulse button is pressed (at transmitter button
operation max. 36 secs).
ON/OFF
(2-button operation)
Each relay can be switched separately.
transmitter button
function
A
or
C
ON
Impulse button
1
st
pressing
B
or
D
OFF
Impulse button
2
nd
pressing
PULSE
(1-button operation)
If a transmitter button or an external impulse but-
ton is pressed, the corresponding relay is trig-
gered for 1 second.
Models
RCL03E5002-01
Degree of protection IP20
RCL04E5002-01
Degree of protection IP65
Technical Details
Frequency:
868.3 MHz
Modulation:
FSK
Coding:
Easywave
Power supply:
12-24 V AC/DC
Current consumption at 24 V DC / 2-ch:
Transmitter operation: approx. 50 mA
Impulse button opera.: approx. 60 mA
Degree of protection: RCL03: IP 20
RCL04: IP 65
Output:
2 potential-free
relay contacts
Max. contact rating:
AC: 24 V / 1 A / 24 VA
DC: 30 V / 1 A / 30 W
Operating temperature: -20°C to +60°C
Dimensions:
RCL03: 70x64x35 mm
RCL04: 72x114x36 mm
Weight:
RCL03: ca. 50 g
RCL04: ca. 100 g
Scope of Delivery
Mini receiver RCL03 or RCL04, mounting
accessories (RCL03: adhesive pad, RCL04:
screws and anchors), operating instructions
Intended Use
The unit may only be operated with safety extra
low voltage (SELV) and may only be used as a ra-
dio control for switching devices with safety extra
low voltage (SELV).
The manufacturer shall not be liable for any dam-
age caused by improper or non-intended use!
RCL03 / RCL04 Mini Receiver
GB
Safety Advice
Carefully read through these instruc-
tions before connecting and operating
the receiver!
Caution!
Observe the permissible supply volt-
age and the max. contact rating!
Have faulty radio controls checked by the
manufacturer!
Do not make any unauthorized alterations or
modifications to the receiver!
ROLLER BLIND MOTOR CONTROL
2-button operation
transmitter button
function
A
or
C
OPEN
STOP
for CLOSE direction
Impulse button CH1
B
or
D
CLOSE
STOP
for OPEN direction
Impulse button CH2
The relay switches off after 90 sec-onds automati
-
cally.
ROLLER BLIND MOTOR CONTROL
3-button resp.
4-button operation
transmitter button
function
A
OPEN
B
CLOSE
C
STOP
D
STOP
Caution:
In this function the impulse buttons CH1
and CH2 are working in the 2-button operation
!
The relay switches off after 90 seconds automati
-
cally.
Mounting and Connecting
1. Remove the housing cover.
2. Using the mounting accessories supplied,
mount the receiver on a suitable location.
Caution:
Make sure there is no interference
with the wireless connection. Do not mount
the device in a distribution box, in metal cas-
ings, in direct proximity to large metal objects,
on the floor or close to it.
The maximum length of all connecting cables
may not exceed 3 m!
3. Select the desired operating mode with jump-
er J1.
4. Connect the supply voltage and the safety
extra low voltage devices to be switched as
follows:
DEAD MAN´S MODE
,
ON/OFF
and
PULSE
:
- Supply voltage
(12-24V AC/DC): IN1, IN2
(at DC: Polarity is arbitrary)
- Device 1 (at relay 1 / channel 1):
NO1 - COM1: NO contact
NC1 - COM1: NC contact
- Device 2 (at relay 2 / channel 2):
NO2 - COM2: NO contact
NC2 - COM2: NC contact
1
J1
4
5
3 2
1
J1
4
5
3 2
1
J1
4
5
3 2
1
J1
4
5
3 2
1
J1
4
5
3 2