The RCL03/RCL04 Easywave mini receiver can 

be operated in a voltage range of 12-24 V AC/DC.
2 potential-free relay outputs may be switched via 

2 separate radio channels. 

A total of 32 different Easywave radio transmis

-

sion codes can be memorized.
It is also possible to connect one external impulse 

button for each channel which can then be used 

to switch the corresponding relay according to the 

selected operating mode.
Four operating modes are available:

-  

DEAD MAN´S MODE 

(factory setting)

-  

ON/OFF

-  

PULSE

-  

ROLLER BLIND MOTOR CONTROL 

for 2-button operation

ROLLER BLIND MOTOR CONTROL 

 for 3-button resp. 4-button operation

Operating Modes

The radio control can be operated in five differ

-

ent operating modes with Easywave transmitters 

for 1-button-, 2-button-, 3-button operation. The 

required operating mode can be selected with 

jumper J1.

DEAD MAN´S MODE 

(1-button operation)
Each relay can be switched separately. The re-

lay is triggered as long as the corresponding 

transmitter button or the corresponding external 

impulse button is pressed (at transmitter button 

operation max. 36 secs).

ON/OFF 

(2-button operation)

Each relay can be switched separately. 

transmitter button

function

or 

C

 

ON

Impulse button  

1

st

 pressing

or 

D  

OFF

Impulse button 

2

nd

 pressing

PULSE 

(1-button operation)

If a transmitter button or an external impulse but-

ton is pressed, the corresponding relay is trig-

gered for 1 second.

Models

RCL03E5002-01      

Degree of protection IP20

RCL04E5002-01      

Degree of protection IP65

Technical Details

Frequency: 

868.3 MHz

Modulation:  

FSK

Coding:  

Easywave

Power supply: 

12-24 V AC/DC

Current consumption at 24 V DC / 2-ch:
 Transmitter operation:  approx. 50 mA
 Impulse button opera.: approx. 60 mA
Degree of protection:  RCL03: IP 20
 

RCL04: IP 65

Output: 

2 potential-free

 

relay contacts

Max. contact rating:
                            AC:   24 V / 1 A / 24 VA
                            DC:   30 V / 1 A / 30 W
Operating temperature: -20°C to +60°C
Dimensions: 

RCL03: 70x64x35 mm

 

RCL04: 72x114x36 mm

Weight: 

RCL03: ca.   50 g

 

RCL04: ca. 100 g

Scope of Delivery

Mini receiver RCL03 or RCL04,  mounting 

accessories (RCL03: adhesive pad, RCL04: 

screws and anchors), operating instructions

Intended Use

The unit may only be operated with safety extra 

low voltage (SELV) and may only be used as a ra-

dio control for switching devices with safety extra 

low voltage (SELV).
The manufacturer shall not be liable for any dam-

age caused by improper or non-intended use!

RCL03 / RCL04    Mini Receiver

GB

Safety Advice

 Carefully read through these instruc-

tions before connecting and operating 

the receiver!

Caution! 

Observe the permissible supply volt-

age and the max. contact rating!
Have  faulty  radio  controls  checked  by  the       

manufacturer!
Do not make any unauthorized alterations or 

modifications to the receiver!

ROLLER BLIND MOTOR CONTROL 
2-button operation

transmitter button

function

or 

C  

OPEN
STOP 

 

for CLOSE direction

Impulse button CH1

or 

D

CLOSE
STOP

 

for OPEN direction

Impulse button CH2

The relay switches off after 90 sec-onds automati

-

cally.

ROLLER BLIND MOTOR CONTROL 
3-button  resp.  

4-button operation

transmitter button

function

A

OPEN

B

CLOSE

C

STOP

D

STOP

Caution: 

In this function the impulse buttons CH1 

and CH2 are working in the 2-button operation

!

The relay switches off after 90 seconds automati

-

cally.

Mounting and Connecting

1.  Remove the housing cover.
2.  Using the mounting accessories supplied, 

mount the receiver on a suitable location.

Caution:

 Make sure there is no interference 

with the wireless connection. Do not mount 

the device in a distribution box, in  metal cas-

ings, in direct proximity to large metal objects, 

on the floor or close to it.

 

The maximum length of all connecting cables 

may not exceed 3 m! 

3.  Select the desired operating mode with jump-

er J1.

4.  Connect the supply voltage and the safety 

extra low voltage devices to be switched as 

follows:

 

DEAD MAN´S MODE

ON/OFF

 and 

PULSE

-  Supply voltage
    (12-24V AC/DC): IN1, IN2
    (at DC: Polarity is arbitrary)
-  Device 1 (at relay 1 / channel 1):
 

 NO1 - COM1: NO contact

 

 NC1 - COM1: NC contact

-   Device 2 (at relay 2 / channel 2):
 

 NO2 - COM2: NO contact

 

 NC2 - COM2: NC contact

1

J1

4

5

3 2

1

J1

4

5

3 2

1

J1

4

5

3 2

1

J1

4

5

3 2

1

J1

4

5

3 2

Отзывы: