Battery check

The battery check function of the ST01 checks 

the battery voltage during the transmission pro-

cedure. In case of a low battery, the battery LED 

blinks once per minute.

Troubleshooting

The receiver does not react to the temperature 

sensor:

 

-

Replace the batteries, if necessary.

 

-

Check that the radio link between the sensor 

and the receiver at the installation site is not 

impaired.

 

-

Reprogram the sensor into the radio recei-

vers, if necessary.

 

-

Other wireless devices using the same fre-

quency and working in direct proximity may 

interfere with the device.

Displaying/setting the operat. mode

T F

PWM

I

/O

OFF

1. 

Press the 

 button to switch between 

the operating modes 

 . 

→ the LED in the right column (F) displays  

  the operating mode of the sensor

→ the LED in the left column (T) display the  

  current temperature and the temperature  

  setpoint

2.  Do not press a button for 10 s to save the 

settings.

→ the LED goes off

UM1

18852  0815  GB

Setting the setpoint temperature

T F

PWM

I

/O

OFF

ODER

1.  Press the 

/

 button to set the set

-

point.

→ the setpoint LED blinks and the LED for  

  the current value lights up

 

 

Are actual value and target value is  

 

identical, the corresponding LED will  

 

flicker.

2.  Do not press a button for 10 s to save the 

setting.

Setting the control mode

T F

PWM

I

/O

OFF

(1.)

(2.)

1.  Press the 

  mode button. The current 

mode is displayed for 10 s.

2.  Within the 10 s, press the 

 button to 

switch between PDM and I/O.

3.  Do not press a button for 10 s.

→ the LED goes off and the sensor returns  

  from setup mode to control mode
→ the settings have been saved

The saved control mode remains 

 

after a battery change.

Display overview

Temperature setting

Function setting

Operating  

modes

Control  

modes

max. value approx. 25 °C

min. value appro. 14 °C

Current value

Setpoint

Sending

Low battery

Day operation

Night setback

Anti-freeze

OFF

ON/OFF

Pulse 

duration 

modulation

Start-Up

Disposal

Waste electronic equipment must not be dispo-

sed of with household waste!

Dispose of the waste product via collec-

tion  facilities  for  electronic  scrap  or  via 

your specialist dealer.
Dispose of used batteries in a recycling 

bin for batteries or via the specialist trade.
Dispose  of  packaging  material  in  the 

recycling  bins  for  cardboard,  paper  and 

plastic.

Warranty

Within the statutory warranty period we undertake 

to rectify free of charge by repair or replacement 

any product defects arising from material or pro-

duction faults. Any unauthorized tampering with, 

or modifications to, the product shall render this 

warranty null and void.

Conformity

This product complies with the essential require-

ments of the R&TTE directive 1999/5/EC.

For use in: EU/CH/FL/IS/N

The  Declaration  of  Conformity  can  be  found  on 

the Internet at: www.eldat.de

Customer service

If the device does not work properly despite

proper handling or in case of damage, please

contact the manufacturer or your retailer.

ELDAT GmbH

Im Gewerbepark 14

15711 Königs Wusterhausen

 

Germany
Phone:    + 49 (0) 33 75 / 90 37-310

Fax:         + 49 (0) 33 75 / 90 37-90

Internet:   www.eldat.de

E-mail:   [email protected]

General information

Отзывы: