background image

C1    Programming the Transmitter

If a previously programmed transmitter is pro-

grammed again in the same output, the previous 

operating mode is
overwritten with the new operating mode.
32 transmission codes can be programmed per 

output.
.

Operation

 

[Press the button]

   Display 

Note

Programming 2TB

P  

1x briefly 

LED 2TB flashes 

Programming mode 2-button operation 

started.

M  

repeatedly  OM number in  

digital display

Select the operating mode (OM).

1/2/3/4

LED 1/2/3/4 and 

 

LED 2TB flashes

Select switching output.  

Only one output can be active at any time, 

change as often as required.

Transmitter 

button

  

Tx 

1x  briefly

LED 2TB and LED 

 

of the selected output 

light up

Transmission code is programmed.  

When all the LEDS go out, the receiver 

 

is ready for operation.

Programming 1TB

P   

2x briefly

LED 1TB flashes 

Programming mode 1-button operation 

started.

M  

repeatedly

OM number in  

digital display 

Select the operating mode (OM).

1/2/3/4

LED 1/2/3/4 and 

 

LED 1TB flash

Select switching output.  

Only one output can be active at any time, 

change as often as required.

Transmitter 

button

  

Tx 

1x  briefly

LED 1TB and LED 

 

of the selected output 

flash

Transmitter is programmed.  

When all the LEDS go out, the receiver is 

ready for operation.

C      Programming

C2  

Setting TIMER II  

The switching times for operating modes 7, 8, 9, 

A and C can be set individually for each output. 
These switching times apply to every transmissi-

on code programmed with this operating mode in 

the output.
The switching time is calculated using the base 

time measured during programming and the mul-

tiplier for the selected operating mode.
The maximum base time is 60 seconds, after this 

time the measurement stops automatically.
The set switching time applies to all of the pro-

grammed transmission codes in this operating 

mode for the corresponding output.

The switching times can be configured individu

-

ally for each output and each TIMER II operating 

mode. 
If the switching time for an operating mode is 

changed, it is also applied to the programmed 

transmitter in this operating mode for the same 

output!

Operation

 

[Press the button]

  

Display 

Note

1.

P  

 1x  briefly

LED 2TB flashes 

Programming mode started.

2.

M  

repeatedly

OM number in  

digital display

Select TIMER operating mode to be set.  

(7, 8, 9, A or C)

3.

1/2/3/4

LED 1/2/3/4 and 

 

LED 2TB flashes

Select output.  

Only one output can be selected.

4.

P   

> 1,6 s 

LED 2TB + 1TB flash 

alternately  

LED 1/2/3/4 light up 

Display counts up the 

seconds

The base time measurement for the timer 

has started. In the display the seconds count 

upwards from 1-10(0) a maximum of 6 times. 

After a maximum of 60 s, the measurement 

automatically stops.

5.

P  

1x  briefly

LED output and 2TB 

 

and 1TB light up

The base time measurement has stopped. 

The measured time is multiplied by the multi-

plier of the chosen OM and the new switching 

time is saved. When all the red LEDS go out, 

the receiver is ready for operation.

If no buttons are pressed within 30 seconds (not during the time measurement), the RCR02 

automatically switches to operating mode. The settings are not saved.

Programming can be cancelled by pressing the P button several times. The order is: 

 

2TB --> 1TB --> Operating mode. In operating mode, all red LEDS and the display are off, 

as long as no output is activated..

Tx

P

M

1/2/3/4

5

Select the 

operating  

mode 

Start program-

ming mode and 

select operation

Select 

output

Send transmission code

Содержание Easywave RCR02E5002A01

Страница 1: ...ordered separately RCR02E5002A01 2TE Technical Data Frequency 868 30 MHz Modulation FSK Coding Easywave Power supply 230 V AC 50 Hz Output 2 potential free relay contacts 16 A normally open Power consumption 0 6 W standby Connected load see Load Table Operating temperature 20 C to 60 C Dimensions W L H 34 5 89 6 62 8 mm Weight 108 g Load Table Load type max load Ohmic load Incandescent lamps 230 V...

Страница 2: ...elect operation Mode button Select operating mode Channel 1 button Manually switch output ON OFF Select output 1 Channel 2 button Manually switch output ON OFF Select output 2 Channel 3 button Manually switch output ON OFF Select output 3 Channel 4 button Manually switch output ON OFF Select output 4 2 A Installing the Receiver A2 Electrical Connection Connection Diagram RCR02 4TE Cable cross sect...

Страница 3: ...e min 100 s max 1 66 h Shutdown warning 30 seconds before the time expires ON retrig OFF ON retrig OFF ON retrig ON retrig ON retrig ON retrig s x 1 Multiplier 1 Switching time min 1 s max 60 s No shutdown warning ON retrig OFF ON retrig OFF ON retrig ON retrig ON retrig ON retrig s x 10 Multiplier 10 Switching time min 10 s max 10 min No shutdown warning ON retrig OFF ON retrig OFF ON retrig ON r...

Страница 4: ...0 0 0 00 30 0 05 00 0 50 00 8 20 00 Conversion seconds with multiplier in time Hr min sec B3 Conversion table of TIMER II Multiplier Seconds Counter 1 10 100 1000 31 1 0 00 31 0 05 10 0 51 40 8 36 40 32 2 0 00 32 0 05 20 0 53 20 8 53 20 33 3 0 00 33 0 05 30 0 55 00 9 10 00 34 4 0 00 34 0 05 40 0 56 40 9 26 40 35 5 0 00 35 0 05 50 0 58 20 9 43 20 36 6 0 00 36 0 06 00 1 00 00 10 00 00 37 7 0 00 37 0...

Страница 5: ...ng mode The maximum base time is 60 seconds after this time the measurement stops automatically The set switching time applies to all of the pro grammed transmission codes in this operating mode for the corresponding output The switching times can be configured individu ally for each output and each TIMER II operating mode If the switching time for an operating mode is changed it is also applied t...

Страница 6: ... respective output are re set Operation 1 Press button Display Note P P 1x briefly or 2x briefly LED 2TB flashes LED 1TB flashes Programming mode started M repeatedly Select delete function L 1 2 3 4 LED 1 2 3 4 and LED xTB flash Select output Only one output can be selected Output can be changed as often as required P until LED output and 2TB and 1TB flash quickly Delete mode started Cancel 1x P ...

Страница 7: ...ent any product defects arising from production or mate rial faults Any unauthorised tampering with or modifica tions to the product shall render this warranty null and void Conformity ELDAT GmbH hereby declares that the radio equipment type RCR02 is in compliance with the Directive 2014 53 EU The full text of the EU declaration of conformity can be obtained at the following internet address www e...

Страница 8: ...UM177683 0519 EN ELDAT GmbH Im Gewerbepark 14 15711 Königs Wusterhausen Germany Phone 49 0 33 75 90 37 310 Fax 49 0 33 75 90 37 90 Internet www eldat de E Mail info eldat de ...

Отзывы: