background image

B  

Operation

B1 

Operating and Display Elements

DISPLAY 

Operating Status

Programming Mode

LED 

GREEN

PWR

Power 

Supply voltage is on, LED 

is lit. 

LED 

RED

2TB

1TB

2-button operation
1-button operation

LED 2TB flashes when a 

wireless signal is detected.

Displays the selected 

operation.
Signals the programming or 

delete mode.

1

LED output 1 flashes

Relay 1 switched

Displays the output selected 

for programming.

2

LED output 2 flashes

Relay 2 switched

3

LED output 3 flashes

Relay 3 switched

4

LED output 4 flashes

Relay 4 switched

Digital Display

.... 

Upon receiving a program

-

med transmission code, the 

corresponding operating mode 

is displayed for 2 s.

Displays the selected opera-

ting mode.
Displays the seconds during 

Timer II programming.

OPERATING 

Operating Status

Programming Mode

Programming button 

Start programming mode, 

select operation

Mode button

Select operating mode

Channel 1 button

Manually switch output  

ON/OFF

Select output 1

Channel 2 button

Manually switch output  

ON/OFF

Select output 2

Channel 3 button

Manually switch output  

ON/OFF

Select output 3

Channel 4 button

Manually switch output  

ON/OFF

Select output 4

2

A  

Installing the Receiver

A2 

Electrical Connection

Connection Diagram RCR02 4TE

Cable cross-sections

rigid cables:

0.5 – 2.5 mm² 

flexible cables with wire 

end ferrules: 

 

0.5 – 1.5 mm²

Connection external antenna

ACC-ANT50-03-21P

Connection external antenna

ACC-ANT50-03-21P

When changing the programming mode, all outputs are switched off and no switching operations 

are possible.

When returned to operating mode, the outputs remain switched off.

 

230 V AC  

50 Hz

N

L

 

230 V AC  

50 Hz

N

L

RCR02 2TE

RCR02 4TE

Connection external 

antenna:

Connect the black anten-

na cable to the antenna 

terminal    

and the white cable to 

the functional earth termi-

nal   on. 

Note: 

Mount the an-

tenna away from metal 

housing.

Connection Diagram RCR02 2TE 

Содержание Easywave RCR02E5002A01

Страница 1: ...ordered separately RCR02E5002A01 2TE Technical Data Frequency 868 30 MHz Modulation FSK Coding Easywave Power supply 230 V AC 50 Hz Output 2 potential free relay contacts 16 A normally open Power consumption 0 6 W standby Connected load see Load Table Operating temperature 20 C to 60 C Dimensions W L H 34 5 89 6 62 8 mm Weight 108 g Load Table Load type max load Ohmic load Incandescent lamps 230 V...

Страница 2: ...elect operation Mode button Select operating mode Channel 1 button Manually switch output ON OFF Select output 1 Channel 2 button Manually switch output ON OFF Select output 2 Channel 3 button Manually switch output ON OFF Select output 3 Channel 4 button Manually switch output ON OFF Select output 4 2 A Installing the Receiver A2 Electrical Connection Connection Diagram RCR02 4TE Cable cross sect...

Страница 3: ...e min 100 s max 1 66 h Shutdown warning 30 seconds before the time expires ON retrig OFF ON retrig OFF ON retrig ON retrig ON retrig ON retrig s x 1 Multiplier 1 Switching time min 1 s max 60 s No shutdown warning ON retrig OFF ON retrig OFF ON retrig ON retrig ON retrig ON retrig s x 10 Multiplier 10 Switching time min 10 s max 10 min No shutdown warning ON retrig OFF ON retrig OFF ON retrig ON r...

Страница 4: ...0 0 0 00 30 0 05 00 0 50 00 8 20 00 Conversion seconds with multiplier in time Hr min sec B3 Conversion table of TIMER II Multiplier Seconds Counter 1 10 100 1000 31 1 0 00 31 0 05 10 0 51 40 8 36 40 32 2 0 00 32 0 05 20 0 53 20 8 53 20 33 3 0 00 33 0 05 30 0 55 00 9 10 00 34 4 0 00 34 0 05 40 0 56 40 9 26 40 35 5 0 00 35 0 05 50 0 58 20 9 43 20 36 6 0 00 36 0 06 00 1 00 00 10 00 00 37 7 0 00 37 0...

Страница 5: ...ng mode The maximum base time is 60 seconds after this time the measurement stops automatically The set switching time applies to all of the pro grammed transmission codes in this operating mode for the corresponding output The switching times can be configured individu ally for each output and each TIMER II operating mode If the switching time for an operating mode is changed it is also applied t...

Страница 6: ... respective output are re set Operation 1 Press button Display Note P P 1x briefly or 2x briefly LED 2TB flashes LED 1TB flashes Programming mode started M repeatedly Select delete function L 1 2 3 4 LED 1 2 3 4 and LED xTB flash Select output Only one output can be selected Output can be changed as often as required P until LED output and 2TB and 1TB flash quickly Delete mode started Cancel 1x P ...

Страница 7: ...ent any product defects arising from production or mate rial faults Any unauthorised tampering with or modifica tions to the product shall render this warranty null and void Conformity ELDAT GmbH hereby declares that the radio equipment type RCR02 is in compliance with the Directive 2014 53 EU The full text of the EU declaration of conformity can be obtained at the following internet address www e...

Страница 8: ...UM177683 0519 EN ELDAT GmbH Im Gewerbepark 14 15711 Königs Wusterhausen Germany Phone 49 0 33 75 90 37 310 Fax 49 0 33 75 90 37 90 Internet www eldat de E Mail info eldat de ...

Отзывы: