![Eldat EasyWave RCL07 Скачать руководство пользователя страница 3](http://html1.mh-extra.com/html/eldat/easywave-rcl07/easywave-rcl07_manual_2377572003.webp)
PROGRAMMING
3
Q/S
programming button
Q/S
R
programming button
R
Tx
transmitter button
OM
Operating mode
Operation
[Press button]
Display LED RCL07
Description
Programming priority transmitter
With priority transmitters, a care call can be initiated even if the RCL07 is deactivated.
Q/S
<1,6 s
Tx
<1,6 s
Q/S
R
1
2
3
4
J2
J1
Q/S
R
1x
R
BA
EIN/AUS
2x
R
BA
IMPULS
3x
R
Betriebs-
bereitschaft
R
<1,6 s
R
<1.6 s
LED R flashes slowly
(1x|break|1x| ...)
Programming mode
OM
ON/OFF
selected
R
<1.6 s
LED
R
flash in cycles of two
(2x|break|2x| ...)
Programming mode
OM
PULSE
selected
Q/S <1.6 s
LED
R
and
Q/S
flash in
cycles of the selected OM
Programming mode priority transmitter
The receiver is in programming mode for approx.
30 seconds. Programming the transmission code
during this period, after the period has expired, the
receiver changes to operation mode.
Tx <1.6 s
LED
R
illuminates
for approx. 4 s
Press the transmitter button and the transmission
code is transmitted.
The operating mode set at the receiver is accepted
with the save procedure and is applicable for
the transmission code saved. Subsequently, the
receiver changes to operation mode.
Flashes the LED
R
quickly for approx. 4 seconds,
all 32 memory spaces are allocated.
Programming acknowledgment transmitter
You can use a acknowledge transmitter to acknowledge a care call received.
Q/S
<1,6 s
Tx
<1,6 s
Q/S
1
2
3
4
J2
J1
Q/S
R
A
B
C
D
Q/S <1.6 s
LED R flashes slowly
(1x|break|1x| ...)
Programming mode ac
knowledgment transmitter
The receiver is in programming mode for approx.
30 seconds. Programming the transmission code
during this period.
After the period has expired, the receiver changes
to operation mode. To cancel the programming
press 2x briefly (<1.6 s) button
Q/S
.
Tx
A/B/
C/D
<1.6 s
LED
Q/S
illuminates
for approx. 4 s
Press the transmitter button with which you wish to
acknowledge. The transmission code (A/B/C/D) is
transmitted and the receiver changes to operation
mode.
Flashes the LED
Q/S
quickly for approx. 4 sec
-
onds, all 8 memory spaces are allocated.
Programming a switching transmitter
Switching transmitter: Activation or deactivation of the care function.
A
B
C
D
Tx
<1,6 s
Q/S
<1,6 s
Q/S
<1,6 s
Q/S
1
2
3
4
Q/S
R
Q/S <1.6 s
LED
Q/S
flashes slowly
(1x|break|1x| ...)
Programming mode ac
knowledgment transmitter
Q/S <1.6 s
LED
Q/S
flash in cycles of two
(2x|break|2x| ...)
Programming mode switching
transmitter
The receiver is in programming mode for the switch-
ing transmitter for approx. 30 seconds. Program
-
ming the transmission code during this period.
After the period has expired, the receiver changes
to operation mode.
To cancel the programming press 1x briefly (<1.6 s)
button
Q/S
.
Tx
A/C
<1.6 s
ED
Q/S
illuminates
for approx. 4 s
Press the transmitter button
A
or
C
, the transmis
-
sion codes are transmitted (Code B and D are
automatically allocated). The receiver changes to
ready for operation.
Flashes the LED
Q/S
quickly for approx. 4 seconds,
all 8 memory spaces are allocated.
ON/OFF
PULSE
Operating
mode
<1.6 s
<1.6 s
<1.6 s
<1.6 s
<1.6 s
<1.6 s
<1.6 s
<1.6 s
Activate
care function:
Press transmitter button
B
or
D
. LED
I/O
flashes green.
Calls are ignored for 15 minutes.
Deactivate
care function: Press transmitter button
A
or
C
. LED
I/O
illuminates green.
Calls are signaled again.