CONTROL AND PROTECTION PANEL FOR IRRIGATION MOTORPUMP

TYPE CEM-330/00

Only for starting and surveillance of the motor pump and stops it if there are anomalies in the parts controlled
by probes.
It has been designed to be installed also on the machine.

NOTICES

Warning:
adhere closely to the following advice

- Always install under other equipment which produces or spreads heat. .
- Always follow the Wiring Diagram on pages 6-7 when making connections.
- Check that the line loading and the consumption of the connected equipment are compatible

with the technical characteristics on page 11.

- All technical interventions must be performed with the engine stationary and terminal 50 of the

Starter motor disconnected.

- Never use a battery charger for the emergency start-up, this could damage the control panel.
- To protect the safety of persons and the equipment, before connecting an external battery

charger, disconnect the electrical plant terminals from the battery poles.

- Never disconnect the battery terminals with the engine running.

THIS CONTROL PANEL IS NOT SUITABLE FOR OPERATING IN THE FOLLOWING CONDITIONS:

- Where the environmental temperature is outside the limits indicated in the Technical Data on page 11.
- Where there are high levels or heat from radiation caused by the sun, ovens or the like.
- Where there is the risk of fire or explosions.
- Where the panel can receive strong vibrations or knocks.

The following maintenance operations should be performed every week:

- check that the indicators function;
- check the batteries;
- check that the conductors are tight, check the condition of the terminals.

CONDUCTION AND MAINTENANCE

ELECTROMAGNETIC COMPATIBILITY

This protection device functions correctly only if inserted in plants which conform with the CE marking standards;
it meets the exemption requirements of the standard EN50082-1 but it cannot be excluded that malfunctions
could occur in extreme cases due to particular situations.
The installer has the task of checking that the disturbance levels are within the requirements of the standards.

YOUR ELECTRICAL TECHNICIAN CAN ASK US ANYTHING ABOUT THIS CONTROL

PANEL BY TELEPHONING ONE OF OUR TECHNICIANS

UNLESS WE MAKE A WRITTEN DECLARATION STATING THE CONTRARY, THIS CONTROL PANEL IS
NOT SUITABLE FOR USE AS A CRITICAL COMPONENT IN EQUIPMENT OR PLANTS RESPONSIBLE FOR
KEEPING PERSONS OR OTHER LIVING BEINGS ALIVE

GB

CEM-330/00 /1

2

Содержание CEM-330/00

Страница 1: ...ction intervention timer oil and battery lights GB CEM 330 00 1 1 BY SIMPLY STARTING IT AUTOMATICALLY CONTROLS THE MOTOR PUMP ALL THE OTHER FUNCTIONS ARE EASY TO USE WITH JUST TWO PUSH BUTTONS PROTECT...

Страница 2: ...ING CONDITIONS Where the environmental temperature is outside the limits indicated in the Technical Data on page 11 Where there are high levels or heat from radiation caused by the sun ovens or the li...

Страница 3: ...n intervention 6 seconds after the pressure drop detected by the PUMPWATER PRESSURE SWITCH fitted on the water pump stops the engine it is memorised and is indicated by the LOW WATER PUMP PRESSURE lig...

Страница 4: ...METER keeps the hours of work in memory even with the battery disconnected CORRECTINGTHE SETTIME CANCELLING THE TIMER Enabled with the key on AUT it makes it possible if necessary to have the engine p...

Страница 5: ...H THE ENGINE STATIONARY NORMALLY THE TERMINAL OF THE OIL PRESSURE SWITCH IS NEGATIVE WITH THE ENGINE STATIONARY NORMALLY THE TERMINAL OF THE THERMOSTAT IS NEGATIVE WHEN THE ENGINE IS TOO HOT NORMALLY...

Страница 6: ...OIL PRESSURE STOPPAGE DUE TO LOW FUEL LEVEL STOPPAGE DUE TO CLOGGED AIR FILTER STOPPAGE DUE TO LACK OF BATTERY CHARGING BROKEN BELT STOPPAGE DUE TO ENGINE OVER TEMPERATURE STOPPAGE DUE TO LOW COOLANT...

Страница 7: ...PROBE AVAILABLE ON REQUEST ACCESSORIES CHARGE BATTERY ALTERNATOR MOUNTED ON ENGINE 1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 11 10 155 3 40 4 150 157 30 BATTERY ORANGE SKY BLUE RED BLACK 40A MAX CONNECTOR CONNECT...

Страница 8: ...E R M I N A L A N D CONNECTITTO EARTH DISCONNECT THE WIRE FROM THE TERMINAL OF THE FLOAT AND CONNECTIT TO EARTH W NOTE STOP GENERAL ALARM AND VISUAL INDICATOR ON WHEN THE SIMULATION HAS BEEN COMPLETE...

Страница 9: ...OF PROBLEM PROBABLE CAUSES REMEDIAL INTERVENTIONS THE STARTER MOTOR DOES NOT FUNCTION Flat battery Starter motor is defective An anomaly indicator is on Defective ignition key Recharge the battery an...

Страница 10: ...ice for the anomaly indicated see PANEL TEST on page 8 and if necessary replace it Check that starter key is in aut engine is running oil pressure switch is disconnected If under these conditions the...

Страница 11: ...previous corrective action taken DIMENSIONS TECHNICAL DATA BATTERY VOLTAGE SUPPLY 12 VDC MAX 16 VDC Or 24 VDC MAX 32 VDC MAX CURRENT OUTPUT YELLOW 3 A RED GREEN GENERAL ALARM 3 A TEMPERATURE RANGE 10...

Страница 12: ...SEE PAGE 7 GB CEM 330 00 1 12 CONFORMITY DECLARATION The company ELCOS s r l assumes full responsability for declaring that the equipment when used in the ways and for the purposes described in the e...

Отзывы: