background image

CONTROL AND PROTECTION PANEL

FOR IRRIGATION MOTORPUMP

TYPE

CEM-330/00

MADE TO:

Motor pump sets by stopping them in the
event of :

oil pressure

over-temperature

belt breakage

minimum fuel level

air filter clogging

low coolant level

low water pump pressure

low

On the front the functions of :

hour meter

pump protection exclusion

protection intervention

timer

• oil and battery lights

GB

CEM-330/00 /1

1

BY SIMPLY STARTING, IT AUTOMATICALLY CONTROLS THE MOTOR PUMP.

ALL THE OTHER FUNCTIONS ARE EASY TO USE WITH JUST TWO PUSH-BUTTONS

PROTECT

DISPLAY

Assembly on the machine and in the open air.

Suitable for stopping both with solenoid and with electromagnet, for engines fitted with charge alternator,

both with pre-excitation and with permanent magnets.

INSTRUCTION

AND

USER

MANUAL

®

PARMA

ITALY

E-mail: [email protected] - HTTP://www.elcos.it

Fax +39 0521/270218

Tel. +39 0521/772021

Содержание CEM-330/00

Страница 1: ...ction intervention timer oil and battery lights GB CEM 330 00 1 1 BY SIMPLY STARTING IT AUTOMATICALLY CONTROLS THE MOTOR PUMP ALL THE OTHER FUNCTIONS ARE EASY TO USE WITH JUST TWO PUSH BUTTONS PROTECT...

Страница 2: ...ING CONDITIONS Where the environmental temperature is outside the limits indicated in the Technical Data on page 11 Where there are high levels or heat from radiation caused by the sun ovens or the li...

Страница 3: ...n intervention 6 seconds after the pressure drop detected by the PUMPWATER PRESSURE SWITCH fitted on the water pump stops the engine it is memorised and is indicated by the LOW WATER PUMP PRESSURE lig...

Страница 4: ...METER keeps the hours of work in memory even with the battery disconnected CORRECTINGTHE SETTIME CANCELLING THE TIMER Enabled with the key on AUT it makes it possible if necessary to have the engine p...

Страница 5: ...H THE ENGINE STATIONARY NORMALLY THE TERMINAL OF THE OIL PRESSURE SWITCH IS NEGATIVE WITH THE ENGINE STATIONARY NORMALLY THE TERMINAL OF THE THERMOSTAT IS NEGATIVE WHEN THE ENGINE IS TOO HOT NORMALLY...

Страница 6: ...OIL PRESSURE STOPPAGE DUE TO LOW FUEL LEVEL STOPPAGE DUE TO CLOGGED AIR FILTER STOPPAGE DUE TO LACK OF BATTERY CHARGING BROKEN BELT STOPPAGE DUE TO ENGINE OVER TEMPERATURE STOPPAGE DUE TO LOW COOLANT...

Страница 7: ...PROBE AVAILABLE ON REQUEST ACCESSORIES CHARGE BATTERY ALTERNATOR MOUNTED ON ENGINE 1 2 3 4 5 6 1 2 3 4 5 6 7 8 9 11 10 155 3 40 4 150 157 30 BATTERY ORANGE SKY BLUE RED BLACK 40A MAX CONNECTOR CONNECT...

Страница 8: ...E R M I N A L A N D CONNECTITTO EARTH DISCONNECT THE WIRE FROM THE TERMINAL OF THE FLOAT AND CONNECTIT TO EARTH W NOTE STOP GENERAL ALARM AND VISUAL INDICATOR ON WHEN THE SIMULATION HAS BEEN COMPLETE...

Страница 9: ...OF PROBLEM PROBABLE CAUSES REMEDIAL INTERVENTIONS THE STARTER MOTOR DOES NOT FUNCTION Flat battery Starter motor is defective An anomaly indicator is on Defective ignition key Recharge the battery an...

Страница 10: ...ice for the anomaly indicated see PANEL TEST on page 8 and if necessary replace it Check that starter key is in aut engine is running oil pressure switch is disconnected If under these conditions the...

Страница 11: ...previous corrective action taken DIMENSIONS TECHNICAL DATA BATTERY VOLTAGE SUPPLY 12 VDC MAX 16 VDC Or 24 VDC MAX 32 VDC MAX CURRENT OUTPUT YELLOW 3 A RED GREEN GENERAL ALARM 3 A TEMPERATURE RANGE 10...

Страница 12: ...SEE PAGE 7 GB CEM 330 00 1 12 CONFORMITY DECLARATION The company ELCOS s r l assumes full responsability for declaring that the equipment when used in the ways and for the purposes described in the e...