background image

GB CBA-030

7

Warning:

Adhere closely to the following advice

Install in such a way that there is always adequate heat disposal.

Always install under other equipment which produces or spreads heat.

Adhere to the instructions and distances indicated for installation.

Check that the absorption and consumption of the connected equipment are compatible with the enclosed

technical characteristics.

Do not try to recharge non rechargeable batteries.

When charging lead batteries, place the battery in a well-aired area.

The connection to the mains must be made in accordance with the national installation rules.

The equipment must be earthed via the relevant terminal.

Connect the equipment to the battery without other conductor cutouts.

Disconnect the equipment output terminals before any interventions on the battery.

Handle and connect without mechanically stressing the electronic card.

Make sure that no copper conductor cuttings or other waste material fall inside the equipment.

THIS BATTERY CHARGER IS NOT SUITABLE FOR OPERATING IN THE FOLLOWING

CONDITIONS:

Where the environmental temperature is outside the limits indicated in the enclosed technical sheet.

Where the air pressure and temperature variations are so rapid as to produce exceptional condensation.

Where there are high levels of pollution caused by dust, smoke, vapour, salts and corrosive or radioactive

particles.

Where there are high levels or heat from radiation caused by the sun, ovens or the like.

Where attacks from mould or small animals are possible.

Where there is the risk of fire or explosions.

Where the battery charger can receive strong vibrations or knocks.

Where the equipment is protected by barriers or casing with protection level less than IP20.

ELECTROMAGNETIC COMPATIBILITY
This  battery  charger  functions  correctly  only  if  inserted  in  plants  which  conform  with  the  CE  marking

standards; it meets the exemption requirements of the standard EN50082-2 but it cannot be excluded that

malfunctions could occur in extreme cases due to particular situations.
The installer is responsible for checking whether the levels of disturbance are above those consented by

the regulations.

CONDUCTION AND MAINTENANCE

The following maintenance operations should be performed every week:

- check that the indicators function;

- check the batteries;

- check that the conductors are tight, check the condition of the terminals.

UNLESS WE MAKE A WRITTEN DECLARATION STATING THE CONTRARY, THIS BATTERY CHARGER

IS NOT SUITABLE FOR USE AS A CRITICAL COMPONENT IN EQUIPMENT OR PLANTS RESPONSIBLE

FOR KEEPING PERSONS OR OTHER LIVING BEINGS ALIVE.

Used only to maintain the battery charge. Used in the starting circuits of diesel and petrol

engines, such as those used in genset units, close-coupled pumps, compressor motors, etc.

Constructed for installation only inside the electric panel.

NOTICES

YOUR ELECTRICAL TECHNICIAN CAN ASK ANY QUESTIONS ABOUT

THIS BATTERY CHARGER BY TELEPHONING OUR TECHNICIAN

Any use which differs from that which is indicated in this instruction and user manual must be authorized

by the manufacturer.

Содержание CBA-030 230/12 V

Страница 1: ...EDIATE AND MAINTENANCE CHARGING WITH VOLTAGE CONTROL SELFPROTECTION AGAINST SHORT CIRCUITING POLARITY INVERSION LOWERING 50 OF THE BATTERY VOLTAGE REMOTE REPETITION FOR INDICATOR LIGHTS SUITABLE TO BE INSTALLED ALSO ON BOARD THE MACHINE INSTRUCTION AND USER MANUAL PARMA ITALY PDLO LQIR HOFRV LW 773 ZZZ HOFRV LW D 7HO ...

Страница 2: ...pen at the same time mains on battery voltage above 65 10 of nominal value The red indicator LED is only lit when at least one of the following conditions happens battery voltage above 65 10 of nominal value polarity inversion battery terminals short circuit If there is overloading of the remote repetition terminals or if there is a mains failure both of the indicators will remain unlit The remote...

Страница 3: ...of air is not obstructed by nearby objects Adhere closely to the indications concerning the minimum distances between the equipment and the surrounding parts If the equipment is installed in a closed cabinet holes or slits should be provided so that the heat can escape Secure the equipment only at the points indicated adhering to the minimum screws cross sectional area AIR Ø4 100 mm 50 mm 50 mm 50...

Страница 4: ...0 3 2 t a r e w o p d e b r o s b a m u m i x a M W 5 0 1 W 4 1 1 t u p t u o g n i g r a h c l l u F 2 4 3 6 e c n e s b a n i g n i d a o l t i u c r i C y l p p u s s n i a m f o V 2 1 t a A m 6 1 V 4 2 t a A m 6 1 s e l o p y r e t t a b e h t t a e l p p i r x a M p p V m 5 p p V m 5 4 1 e 2 1 1 1 s t u p t u o n o d a o l x a M W 3 W 3 1 1 t u p t u o n o e g a t l o v l a c i p y T V 6 1 V ...

Страница 5: ...GB CBA 030 5 127 6 ...

Страница 6: ...GB CBA 030 6 127 6 ...

Страница 7: ... by the sun ovens or the like Where attacks from mould or small animals are possible Where there is the risk of fire or explosions Where the battery charger can receive strong vibrations or knocks Where the equipment is protected by barriers or casing with protection level less than IP20 ELECTROMAGNETIC COMPATIBILITY This battery charger functions correctly only if inserted in plants which conform...

Страница 8: ...ction WARNING COMPONENTS CARRYING DANGEROUS VOLTAGE LEVELS CONFORMITY DECLARATION The company Elcos s r l assumes full responsabilty for declaring that the equipment type CBA 030 installed and used in the ways and for the purposes described in the instruction and user manual is in conformity with the following directives 2006 95 CE related to the electrical materials destined to be used within cer...

Отзывы: