Menu: Domestic hot water
Target values
Domestic hot water can be regulated
according to different target values.
These target values come into
effect with the selected operating
mode, thereby resulting in different
temperature levels in the DWH tank.
TWWR
DHW reduced target value
TWWN
DHW nominal target value
TWWmax Maximum DHW nominal target value
Menu: Boiler
Line no.
Operating line
Factory setting
1610
Nominal target value
55°C
1612
Reduced target value
40°C
Line no.
Operating line
Factory setting
2214
Target value for manual operation
60 °C
Target value for manual operation
Boiler temperature target value,
which is set during activated manual
operations.