Maintenance
Cleaning the condensate receptacle
Cleaning and refilling the syphon
Inspection of combustion chamber
22
Cleaning the condensate receptacle
Disconnect the plug of the fluegas
temperature sensor (1);
Remove the condensate receptacle
(2);
Clean the receptacle;
Mount the condensate receptacle;
Connect the plug of the fluegas tem-
perature sensor.
Cleaning and refilling the syphon
Remove the syphon (3) from the con-
densate connection;
Clean and fill it with fresh water;
Mount the syphon back in the original
position.
Inspection of combustion chamber
For inspection of the combustion cham-
ber the mixing system and burner must
be disassembled.
Switch off the boiler and close the gas
supply;
Remove the electrical connection
from the fan and gas valve (4);
Remove the electrical connection
from the electrodes (5);
Undo the gas connection at the inlet
of the gas valve (6);
Disassemble the top plate incl. mixing
system (7);
Remove the burner from the
combustion chamber (8);
Inspect the combustion chamber and
clean it with a vacuumcleaner if
necessary;
Assemble all components in opposite
order;
Open the gas supply and check all
connections for gas leakage;
Switch on the boiler.
1
2
5
4
6
7
8
3