It  is  possible  to  continue  the  serial  line  using  the  same 
connector  (see  Paragraph  10.6).  In  this  mode,  the  termination 
resistor  will  not  be  placed  at  the  end  of  the  battery  of  the 
ELK22MP devices but it must be the device to which the line is 
connected that must have the termination resistor. To do this, 
disconnect the resistance from the accessory and continue the 
line with the cables for RS485 as below screenshot shwon 

 
 
 
 
 
 

 

 
 

4.7 – IMAGE CONNECTION 
 
4.7.1 – ELK22MP Stand Alone 

 

4.7.2 – ELK22MPM Stand Alone 
 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

4.7.3 – ELK22MPE Stand Alone 

 

 

 
 

4.7.4 – ELK22MP with at most 15 ELK22MPS 

 

 

 

4.7.5 – ELK22MPM with at most 15 ELK22MPS 

 

4.7.6 – ELK22MPE with at most 31 ELK22MPS 

 

 

7 - pole RX (-) 
8 - pole TX (+) 

Содержание ELK22MP

Страница 1: ...1 For normalized signals 4 20mA 0 10V It is designed for mounting on a din rail The ELK22MP series consists of 4 models 3 of these act as a centralizer and one of them as a slave The models of the ELK...

Страница 2: ...he menu to select a module 5 4 red digits Process value during operation parameter selected during programming 6 4 green digits Setpoint value during operation value of the parameter selected during p...

Страница 3: ...munication speeds adopted range from 1200 to 38400 baudrates and allow very satisfactory performances while remaining well below the limits imposed by the RS485 standard This allows the line to be wir...

Страница 4: ...ters of the instrument can be read and written via serial communication The configurable parameters are found in Paragraph 6 4 WARNINGS FOR INSTALLATION AND USE 4 1 PERMITTED USE The device has been d...

Страница 5: ...and a maximum of 1 to 31 slave devices A devices sequence that have ELK22MPM or ELK22MP as a centralizer must consist of a centralizer device and a maximum of 1 to 15 slave devices Two control units...

Страница 6: ...must be the device to which the line is connected that must have the termination resistor To do this disconnect the resistance from the accessory and continue the line with the cables for RS485 as bel...

Страница 7: ...programming the parameter Cont ON FN the parameter OxF H REG the parameter OyF C REG The adjustment operation operates on outputs depending on the measurement of the setpoint SP1 and hysteresis HPOS...

Страница 8: ...nect one ELK22MP at time and set the ADR parameter before connect the next ELK22MP Example connect and power up the first ELK22MP program the ADR parameter to 0 and power off the system Connect the se...

Страница 9: ...6 LHdo None 0x19 25 AL2 Alarm threshold SSP FSP 0 0x1A 26 HAL2 Hysteresis of alarm remedy 0 100 1 0x1B 27 AL2D Delay of alarm remedy 0 100 0 sec 0 0x1C 28 ADR Module address 1 16 16 0x1D 29 For each m...

Страница 10: ...LSB byte 0 byte1 0x06 byte 2 byte 3 byte 4 byte 5 byte 6 byte 7 7 4 FUNCTION 7 READ ALLARM STATUS The request has the following frame Slave number Function number CRC LSB MSB byte 0 byte1 0x07 byte 6...

Страница 11: ...the following frame Slave number Function number First word address MSB LSB Value to write MSB LSB byte 0 byte1 0x06 byte 2 byte 3 byte 4 byte 5 The normal reply is merely an echo of the request messa...

Страница 12: ...ay outputs and front reinforced between low voltage parts 24 and 240 power supply and relay outputs and low voltage parts static inputs and outputs reinforced between power supply and relay outputs re...

Страница 13: ...ption of the probe Check that the probe is correctly connected to the device and then verify that the probe is working properly 11 2 CLEANING It is recommended to clean the device only with a slightly...

Отзывы: