Choose proper knock-outs to fix the junction box on the surface
of ceiling board with two wood screws attached with rubber
washer (See FIG.17).
Take off sensor's two spring clips (See FIG. 12), turn the decorative
frame of sensor anti-clockwise with proper strength, then insert
the 4 non-dropping screw to the corresponding screw holes on
sensor's front cover. Afterwards, those 4 screws will not drop off
to provide conveniences to the subsequent installations
(See FIG.18).
Refer to wiring diagrams for correct wiring connection See FIG.5
- FIG.7).
There is a " " symbol on the side of the surface of junction box,
the housing of EKO07042 and the decorative frame
respectively for position verified convenience. Keep the " "
symbol on the junction box and sensor's front cover in line to
assemble them with the attached 4 non-dropping screws, then
cover up the sensor's decorative frame (See FIG.19) and turn it
to be tight.
Rubber
washer
FIG.17
FIG.18
Non-dropping
screw
Non-dropping
screw
3
16
EKO07042
Occupancy Sensor
en