Technical Data
AEROTOP T07(C)-T16
Heat pump type AEROTOP T
T07(C)
T10(C)
T12(C)
T14
T16
Heating operation
For
A2/W35
Heating Capacity
Qh
kW
6.4 9.1 11.8 13.7 14.8
Power input
Pel
kW
2.0 2.8 3.4 3.9 4.1
Performance number EN14511
COP
-
3.3 3.3 3.5 3.5 3.6
Heating operation
For A7/W35
Heating Capacity
Qh
kW
8.1 11.5 13.6 15.8 17
Power input
Pel
kW
2.0 2.9 3.4 3.9 4.2
Performance number EN14511
COP
-
4.0 4.0 4.0 4.0 4.1
Condenser
Scroll hermetically
Maximum current consumption
lmax.
A
6.3
10
11
13
13.5
Start-up current with smooth starter
VSA
A
15.75
25
27.5
32.5
33.75
Current intensity with blocked rotor
LRA
A
40
50
66
74
74
Current connection
V-f-Hz
400-3-50
Fuse
WP
A/T
16 16 16 20 20
Fuse WP with electrical insert
A/T
20
20
20
25
25
Condenser, heater side
Material: Chrome steel AISI 304, 1.4301
Hydraulic connections
IG
Zoll
1”
1”
1”
1”
1”
Water content incl. connection hoses AEROTOP TC
l
53
53
53
-
-
Water content incl. connection hoses AEROTOP T
l
2.6
3
3.1
3.4
3.4
Volume stream heating operation nom/min
1)
l/h
1500/568 2100/835 2700/999 3070/1171 3100/1300
Pressure loss heating operation
AEROTOP TC
kPa
8.4/2.1
16.4/4.1
22.8/5.7
AEROTOP T
kPa
28.3/4.4
32.9/4.1
33/4.5
36.5/4.6
35.5/5.5
Residual pressure AEROTOP TC
2)
kPa
51.4
57.9
55.4
Expansion tank heating AEROTOP TC
V
l
12
12
12
-
-
Primary pressure heating-circuit expansion tank
p
bar
1
1
1
-
-
Evaporator/fan
Volume stream
m
3
/h
2'500 3‘300 5'300 6'300
6'800
Available pressure
3)
Pa
150 92 146 112
82
Power consumption fan
4)
P
kW
0.035 0.100 0.100 0.170
0.210
Maximum current consumption fan
lmax.
A
1.6
1.6
1.6
2.1
2.1
Coolant
R407C
Coolant filling AEROTOP TC
kg
1.9
2.95
3.7
-
-
Coolant filling AEROTOP T
kg
2.5 3.1 3.7 4.1 4.1
Coolant circuit oil
-
Ester oil
Oil quantity
l
1.1
1.36
1.85
1.65
1.89
Weight heat pump
AEROTOP TC
kg
239
274
299
-
-
AEROTOP
T
kg 204 246 272 276 279
Indoor setup
Sound power level
6)
On suction
7)
Lwa
dB(A)
53.0 56.0 54.0 59.0 61.0
On exhaust
7)
Lwa
dB(A)
48.0 53.0 50.0 53.0 55.0
Inside
Lwa
dB(A)
50.0 54.0 55.0 60.0 60.0
Outdoor setup
Sound power level standard configuratuion
Lwa
dB(A)
62.0 65.0 61.0 66.0 70.0
LP pressure control OFF-switch off
p
bar
0.2
LP pressure control ON- switch on
p
bar
1.6
HP pressure control OFF-switch off
p
bar
29.0
HP pressure control ON- switch on
p
bar
24.0
Sound pressure level standard configuratuion in 1 m
Lpa
dB(A)
51.0
54.0
50.0
55.0
59.0
Maximum
working
pressure
p
bar
3 3 3 3 3
1) Min:
∆
t max= 10 K, with PHW-preparation
∆
tmax = 5 K. (V' [l/h]= Qh[kW]/(4.18*
∆
t[K]*
ρ
[kg/l])*3600)
2) Residual pumping pressure is stated for maximum pumping stage.
3) At maximum fan rotational speed.
4) At fan rotational speed setting B (T07(C), T10(C), T12(C), T14, T16).
5) Data for star/V connection of the electric motor. The machines are factory-equipped with star connection.
6) Measuring according to DIN ISO 9614-2. Sound power level is a property of the source of noise and therefore dependent on the
distance; it describes the totality of the sound power of the corresponding source radiating in all directions. Information to determine
the noise level see planning documents.
7) Information without consideration of a light well or air duct, which reduce the noise level considerably. Screen noise absorbers
reduce noise by 6-7 dB(A).
16
Содержание AEROTOP T Series
Страница 87: ...Notes 87...