Страница 2: ...0 Recover from new tube 16 Air purge 17 Usage Information 17 Setting 18 Calibration 20 Weight calibration 20 Vacuum calibration 21 Pressure calibration 22 Inverter 23 Maintenance 15 Compressor Mainten...

Страница 3: ...50Hz Display 4x20 character LCD Storage tank capacity 6 kg Scale resolution 5 gr Compressor 1 4 HP 8 cc hermetic Recovery rate 250 gr min maximum Operating range 8 C to 49 C Low pressure gauge 15 bar...

Страница 4: ...Avoid contact of liquid refrigerant with the eyes and prolonged skin exposure Pressurized tank contains liquid refrigerant Never fill the refrigerant tank to more than 80 of its maximum capacity Hose...

Страница 5: ...ORATOR An evaporator is a device in a process used to turn the liquid form of a chemical substance such as water into its gaseous form vapor The liquid is evaporated or vaporized into a gas form of th...

Страница 6: ...6 35 Components 1 Pressure Gaugess 6 Dryer Filter 11 Compressor 2 On Off button 7 nverter optional 12 Condenser 3 Control Panel 8 Oil Seperator 13 Vacuum Pump 4 New oil bottle 9 Gas tank 14 5 Used oil...

Страница 7: ...www elcielektronik com 7 35 Control Panel elcielektronik com...

Страница 8: ...first use 1 Place the unit on a flat surface 2 Connect quick action coupler valves to the service hoses DO NOT OVERTIGHTEN 3 Remove aluminum foil from the vacuum pump and install oil filler cap 4 Remo...

Страница 9: ...nt from the A C system 4 If you see the warning OPEN USED OIL VALVE open used oil valve SLOWLY 5 If you see the warning CLOSE USED OIL VALVE close used oil valve then press ENTER 6 Screen will display...

Страница 10: ...Operations 2 Charge Refrigerant Uses to charge vehicle A C system with refrigerant 1 Connect service hoses to the vehicle and open adapters 2 Select CHARGE REFRIGERANT then press ENTER 3 There is two...

Страница 11: ...clude the vacuum time Leak control amount of gas manually 1 VACUUM TIME Vacuum time entered to make the air conditioning system vacuum NOTE The purpose of this process is to remove the air water vapor...

Страница 12: ...eteriorating 1 Screen will display LEAK CONTROL TIME 2 Use UP DOWN buttons to set the desired time 3 To skip leak control operation set the time to zero 4 Press ENTER to proceed WARNING Unit will stop...

Страница 13: ...5 Operations 3 AMOUNT OF GAS The purpose of this process is to enter the amount of gas we want to apply to system NOTE in order to get better results we have to add gas 30 40gr hose amount to the amou...

Страница 14: ...firstly required to Add New Oil 1 Screen will display ADD NEW OIL 2 Use UP DOWN buttons to select YES or NO 3 Skip oil injection by selecting NO 4 Press ENTER to proceed WARNING Open oil valve when yo...

Страница 15: ...to add the amount of gas which is the hose share in this process Vehicle Database Select vehicle brand and model to charge vehicle A C system with refrigerant 1 Select VEHICLE DATABASE then press ENTE...

Страница 16: ...rvice hoses to the external tank and open tank s valve 2 Open the valve of the connected service hose close the other one on manifold 3 Use UP DOWN buttons to select REC FROM VEHICLE then press ENTER...

Страница 17: ...to leaks in the system The unit will perform automatic air purge when sensors detect excess air in the storage tank Operation time might differ depending on the amount of air in the tank Usage inform...

Страница 18: ...www elcielektronik com 18 35 Setting Press and hold ESC button on the main menu screen for 5 seconds to enter the calibrations and settings To obtain a password call the manufacturer service...

Страница 19: ...2 DIL LANGUAGE Turkish and English languages are registered in it s own memory User s request the desired language is loaded onto 3 SYSTEM VACUUMING It is a process used to vacuum the system 4 SERVIC...

Страница 20: ...ct that we know the net weight A TARE to reset the weight of machine own tank weight B WEIGHT CALIBRATION when you choose this menu it is automatically measured and the object which you know the weigh...

Страница 21: ...b For calibration open manifold valves and press ENTER c After a beep warning close the manifold valves and press ENTER d Machine automatically starts to countdown a timer and the number beside it als...

Страница 22: ...e of machine is equalized to the atmospheric press 2 GAIN to perform this operation Combine manifold outlets with a single hose and open manifold valves Charge 100 gr Refrigerant Note the pressure of...

Страница 23: ...used to provide 220 volts of energy required for operation of the device Usage Attach the power cable of the device to the socket on the back of the device Attach the RED wire of the inverter to the s...

Страница 24: ...NGE COMPRESSOR OIL 1 Detach the hose from the drier filter to the compressor 2 Use new oil bottle to fill in approximately 70 gr of oil with the help of TEST menu 3 Re attach the hose 4 Go to main men...

Страница 25: ...xpired filters voids warranty EKM plus filters need to be replaced every 100 kg of operation After 80 kgs of operation the unit will start reminding the user at every start up When the filter reaches...

Страница 26: ...y 30 working hours or when filter drier is replaced When the color of the oil becomes dark or cloudy 1 Obtain an empty container to collect the used oil 2 Disconnect the unit from the electrical suppl...

Страница 27: ...constricted Straighten hose Unit does not recover Manifold valve closed Open valve Leak in vehicle AC system Find and repair leak Service adapters closed Open adapters Scale calibration error Re cali...

Страница 28: ...edied within 15 working days the manufacturer and importer must allocate another industrial product with similar functions to the use of the consumer until repair of product is completed National lega...

Страница 29: ...e certificate of warranty you may refer to the General Directorate for the Protection of Consumers and Competition of the Ministry of Industry and Trade 12 Even though the consumer uses its right of r...

Страница 30: ...RKING SITES 1354 STREET 1357 Qr NO 30 YEN MAHALLE ANKARA T RK YE TELEPHONE 90 312 395 53 53 PBX FAX 90 312 395 18 86 PRODUCT TYPE REFRIGERANT RECOVERY RECYCLE RECHARGE MACHINE BRAND ELC MODEL EKM PLUS...

Страница 31: ...oils recommended by the manufacturer Refrigerant Tazetti Solkane AG Adge Arkema Honeywell Chemours Compressor oils PAO compressor oil Reniso PAG Reniso Triton SEZ 68 POE Reniso Triton SE 170 POE Vacu...