Manuale di istruzioni/Scheda tecnica

La divulgazione dei dati contenuti in questa scheda è da ritenersi un servizio puramente informativo e non costituisce alcun vincolo da parte della Elcart in merito a prestazioni ed utilizzo del prodotto.

The divulgation of data contained on this technical sheet are exclusively for informational reasons and establish no link on behalf of Elcart regard to thr performances and the usa of the product.

La divulgacion de los datos contenidos en esta ficha son un servicio unicamente informativo y no constituyen ningun vinculo de parte de Elcart respecto a las prestaciones y uso del producto.

ART. 09/06015-00

PAGINA 2 DI 2

Non-contact Alternating Voltage Tester

Operation Manual

ART. 09/06015 NI 405

 

Warning

Special attention is required when using this device, because the improper 

use may cause damages to this device or bodily injuries. Please fully abide 

by the safety rules and safety measures as provided for herein. 

Structural Diagram:

 

 Probe (NVC sensor)

 Power switch

 Electric torch switch

 Induced voltage indicator lamp

 Signal intensity indicator lamp (low)

 Signal intensity indicator lamp (moderate)

 Signal intensity indicator lamp (strong) - red  

 Electric torch illumination lamp

Operating instructions:

 AC Voltage Detection

Turn on the instrument's power switch 

, and the power indicator lamp 

(white) illuminates. Allow the instrument's probe to contact the power socket 

orto get near the live wire. If the instrument detects  AC voltage, its induction 

indicator lamp 

 will flash. 

The relevant signal intensity indicator lamps (low, mid, high) light up, 

depending on the signal intensity detected, and the buzzer makes the 

different alarm sound. 

• if the instrument detects common AC signal, the signal intensity 

indicator lamp (low) alone lights up; 

• if it detects higher AC signal, the signal intensity indicator lamps (low, 

mid) both light up; 

• if it detects highest AC signal, the signal intensity indicator lamps (low, 

mid, high) all light up.

  

 

Warning

1. If the AC voltage is detected, this indicates the presence of voltage, even 

though there is no alarm indication. The presence of voltage cannot be 

judged by the non-contact voltage tester. The detecting operation may 

be affected by such factors as socket design, insulation thickness and 

insulation type.

2. Before the instrument is used for detecting the AC voltage of the power  

socket etc, the test pencil should be tested on the given live circuit, to 

make sure that it may work well.

Specifications:

Technical indicators

Range of AC voltage

12 -1000V

Frequency

50 Hz/60Hz

Alarm mode

Sound and light alarm

Electric torch

White LED illumination lamp

Auto shutdown

Low-voltage indicator lamp

Zero/live line judgment

Sound (different frequency) and LED lamp

NCV sensitivìty

Selecting 3 types of sensitivity automatically 

(low, mid, high)

NCV sensitivity indication 

mode

The instrument uses the alarm sound 

of different frequency and LED lamp of 

different color to indicate low, moderate or 

high sensitivity

General Parameters

Power source

2x1.5V AAA cell

Product size

156x20x20 mm

Product weight

45 gr.

Security level

CE CATIII 1000V/CAT.IV 600V

Service temperature

0°C÷+40°C

Storage temperature

-10°C÷+50°C

Altitude

<2000m

Auto Shut-Down

If the instrument is not operated and detects no AC voltage within three 

minutes, it will turn OFF automatically.

Low voltage indicator lamp: 

when the cell voltage is less than around 

2.6V, the power indicator lamp will flash three times for alarm, and the buz-

zer will sound once, before the instrument turns OFF automatically. The cell 

is to be replaced.

Electric torch: 

the electric torch lights up when the electric torch switch 

 

is pressed, and goes out when the switch is again pressed. If the switch is 

turned ON, the electric torch will go out automatically 5 minutes later.

Cell Replacement:

As per the diagram below:

1) Rotate the cell cover

2) Take out the used cell;

3) Put a new cell in as per cell anode and cathode indication

  

 

Warning

To avoid electric shock, do not use this instrument before the cell cover is 

replaced.

Cell rotation direction 

as indicated 

User information ex art. 26 D. 49/2014

The symbol labelled on the appliance (Annex IX D. 49/2014) indicates that 

the rubbish is subject to “separate collection” and it has been placed on the 

Italian market after the December 31, 2010.

The  user  must  therefore  assign  or  (have  collected)  the  rubbish  to  a 

treatment facility according to indications by the local administration, or 

hand it over to the reseller in exchange for an equivalent new product. The 

separate collection of the rubbish and the subsequent treatment, recycling 

and disposal operations encourage the production of appliances made 

with  recycled  materials  and  reduce  negative  effects  on  health  and  the 

environment caused by improper treatment of rubbish. 

In the case of very small WEEE (no external dimension more than 25 cm), 

the user is eligible to get free of charge assignation to retail shops with sales 

areas relating to EEE of at least 400 m². 

Made in China

IMPORTED AND DISTRIBUTED BY:

ELCART DISTRIBUTION SPA

Via Michelangelo Buonarroti, 46

20093   COLOGNO MONZESE   (MI)

ITALY

www.elcart.com - [email protected]