Manuale di istruzioni/Scheda tecnica
La divulgazione dei dati contenuti in questa scheda è da ritenersi un servizio puramente informativo e non costituisce alcun vincolo da parte della Elcart in merito a prestazioni ed utilizzo del prodotto.
The divulgation of data contained on this technical sheet are exclusively for informational reasons and establish no link on behalf of Elcart regard to thr performances and the usa of the product.
La divulgacion de los datos contenidos en esta ficha son un servicio unicamente informativo y no constituyen ningun vinculo de parte de Elcart respecto a las prestaciones y uso del producto.
ART. 28/2251
PAGINA 26 DI 36
INTRODUCTION
An UPS (Uninterruptible Power Supply) is a static electricity generator which
ensures a continuous supply, constant, high quality and reliability for the devices to
protect. A UPS is a device that protect computers and computer networks,
communications infrastructure, telecommunications, finance, transportation, national
defense, schools, hospitals, scientific research institutes, etc..
1) FUNCTIONS AND FEATURES
1.Input and output IGBT module, can ensure a life expectancy of product more than
300.000 hours.
2.Totally chekcked by digital proprietary algorithm to ensure optimal management of
the group parameters.
3.Automatic boot to prevent potential problems or failures to the unit.
4.Double conversion technology can guarantee without any switching or interrupt the
power supply.
5.Technology owner compensation voltage that allows the group to work from 115
volts to 295 volts without using battery power.
8.Frequency is 50Hz or 60Hz, automatically controlled, with a 10% tolerance.
9. PFC (Power Factor Correction) input guarantees the input power factor> 0.98,
increasing efficiency and decreasing the group's maximum harmonic distortion from
the input to the network group.
10.Fully automatic in the presence and absence of network entry, with re-start
automatically in case of long power failure.
11.Battery turn on opertation for emergency situations that require the group to start
with zero network input.
12.Total protection group from mains voltage is too low or high overloads and short
circuits from high internal temperatures, from over-discharge of batteries, etc..
13. Rack-Tower with LCD display. The display rotates characters by simply pressing
a button. The information available on the display, the percentage of the load to the