ENG man MITO-MINI-915 04
Radio Remote Control System MITO-A-MINI
- Page 14 -
3.4 PIN CODE PROGRAMMING
PIN CODE
ENABLING
(submenu3)
SUBMENU ACCESSED.
HERE YOU CAN ENABLE OR DISABLE
PIN CODE FOR TRANSMITTER LOCK.
AUTOMATIC RETURN TO MAIN MENU;
WAIT 10 SECONDS AND SYSTEM EXITS MAIN MENU.
NOTE
- This function may only be programmed in continuous trasmission mode (CT);
- no default pin code is set at the factory;
- if you forget the pin code unlock sequence, you will need to programme a new sequence or disable pin code lock before
you can use the transmitter.
FROM MAIN MENU,
ACTIVATE T4
T4
EXAMPLE:
pin code lock setting T9-T10-T11
ENABLING
FOR CT ONLY
FROM SUBMENU3,
ACTIVATE A
SEQUENCE OF 3
CHANNELS
BLINKS 3 TIMES
AT 1Hz
NOW SET ANY GIVEN COMBINATION OF 3 CHANNELS
(E.G. T2, T3, T2).
WHEN THIRD CHANNEL IS ACTIVATED,
SEQUENCE IS STORED AS PIN CODE ENABLE.
AUTOMATIC RETURN TO MAIN MENU;
WAIT 10 SECONDS AND SYSTEM EXITS MAIN MENU.
DISABLING
FOR CT ONLY
FROM SUBMENU3,
ACTIVATE T1
PIN CODE DISABLED
AUTOMATIC RETURN TO MAIN MENU;
WAIT 10 SECONDS AND SYSTEM EXITS MAIN MENU.
T1
T2 or T3 or T4
or T9 or T10 or T11
CHANNELS
TO BE USED
WHAT TO DO
CHECK LIGHT
BLINKS 3 TIMES
AT 1Hz
BLINKS TWICE
QUICKLY WITHIN
1 SEC.
T11
CHECK
T1
T12
CHECK
CHECK
T4
T10
T9
1
2
3
STEP 1
access to
programming mode
STEP 2
access to
pin code submenu
STEP 3
programming
pin code sequence
EXAMPLE:
Disabling auto-shutdown
T11
CHECK
STEP 1
access to
programming mode
T1
T12
T3
CHECK
STEP 2
access to auto-shutdown
time submenu
CHECK
STEP 3
disabling
auto-shutdown