A - RADIO CODE PROGRAMMING
(A code different from basic code)
possible to program
different standard codes or
It’s
A1 - Set a new code in hand set
A2 - Push
the white button on the main PCB ONCE THE
should
come on.
A3 - Send an impulse or signal from hand set from a minimum distance of 0,5
meter the OK led should go out for about 0,5 second, indicating the
memory has accepted the new code. It’s possible to store more codes in the
memory, when the memory becomes full the OK led will falsh 2 times to
indicate the memory is full.
A4 - To leave the programing procedure press
twice, the OK led goes out
A5 - If you need to cancel codes from the memory :
Press and hold down
turn power off and after a few seconds still
holding down
switch power back on the PCB is now back to
factory setting
61
15 rolling codes
P1
OK LED
P1
P1
P1
P1
Led OK
A2
Led OK
50 cm
Turn off
0,5 sec
A3
P1
Led OK
2 impulses
A4
P1
Switch
omnipolar
230V 50Hz
A5
B- STOP CODE PROGRAMMING
<<< not available at the moment >>>
P1
Led OK
B1
Led OK
STOP
STOP
3
5
B2
P1
Led OK
2 impulses
B3
AMALTEA2 is the appropriate control board to operate motors with incorporated limit switch,
you’ll find it ready having a BASIC PROGRAM given from the factory :
> working time = 30 seconds
> radio code in memory = dips 1-3-5-7-9 ON channel n.1
( transmitter’s base code )
> without automatic closing
( courtesy lamp timing = 3 min.)
R -
It is possible to return to the BASIC CODE or PROGRAM :
R1 - Switch ELECTRICAL supply off turn dip switches 1 and 2 ON
R2 - While holding P1 down turn power on
R3 - The OK LED goes off for about 1 second at this time release P1 and
turn dip switches n.1 and n.2 off
( the program is back to basic code)
RESET
B1 - Push the button
The OK led goes on.
B2- Open the stop contact (terminals 3-5) send a code from the
hand set, the OK led goes off for 1 sec.
B3 - For came out of programming push 2 times the button
P1.
P1.