This manual contains very important instructions for the installation, and use of this control board mod.
Do not install prior to reading this manual, the best results depends upon the correct application , installation.
We the manufactures of this product declines any responsibility in the case of an incorrect installation or improper use ,
And should be installed by a qualified person. This product has been created by keeping the strictest safety norms following
EC directives : CEE73/23, CEE89/336, CEE93/68, CEE89/106, CEE89/392.
AMALTEA-2.
STOP
P1
Led ON
OK
RECEIVER
DIP
Led
A
B
C
Courtesy Light
Flashing light
Motor
Com
220Vac
Antenna
Stop
Button.
Start/Stop
C
B-
A
- Only rolling code
Theft proof’s function
- Tampering
Off ON
1 Pause
2 Times
omnipolar
230V 50Hz
4 5
1 2 3 4 5
TX
24
V
a
c
Photocell
Photocell
TERMINALS CONNECTION
1-2
3-5
4-5
6-5
7-8
9-10
11-12-13
14-15
power supply 230 Vac - 50 Hz
)
11-14
ANTENNA terminal n.1=RF
STOPcontact, normally close.
PHOTOCELL contact, normally close
START/STOP contact, normally open
output 24 Vac max feeding 2 photocells
courtesy lamp contact (max 5A-230V) free voltage contact
connection for monophase motor 500W max (terminal n.11=common)
flashing light connection 230 V - 25 W
(TERMINAL 14=NEUTRAL
!
FOLLOW THESE INSTRUCTION CAREFULLY !!!
!
ATTENTION !!
During the installation it’s important to have a switch with
contact opening of at least 3mm that assurse an omnipolar
disconnection of the board to the current network . Procede
with a correct motor grounding.
Control board for
rolling-shutters and
blinds’ automation with:
-rolling code
-cortecy lamp contact
Amaltea 2
Soldering bridges
RX
1
Switch
ELCA snc
Tel. 0039 0734 608484
Via Malintoppi, 32
Fax 0039 0734 605080
63023 FERMO (AP)
e-mail: [email protected]
ITALY
web: www.elcasnc.com
This manual has to stay with the equipment at all time, must not remove!
!
FOR SAFETY REASON A SAFETY DEVICE
MUST BE USE WHEN USING THIS REMOTE CONTROL