background image

Operation 
 

The user interface consists of 4 illuminated momentary 
pushbuttons, located on the front panel. 
They are labeled: 

REC, STOP, PLAY and LOOP.

 

 
 

REC STOP 

PLAY LOOP 

 
Record 
 

Puts the device in RECORD READY, waiting for a DMX 
change to start recording. This state is indicated by blinking of 
the RECORD led. Depressing STOP will cancel the RECORD 
READY status. 
  Pressing RECORD the second time before a DMX change 
starts recording anyhow. The RECORDING status is shown by 
full illumination of the RECORD led. 
  Depressing STOP will give a RECORD PAUSE condition, 
indicated by an illuminated RECORD led and a blinking STOP 
led. From here on one can go on with recording via RECORD, 
again waiting for a DMX change or depressing RECORD 
again or stop by pressing STOP for the second time. 
The DMX signal to be recorded has to be applied to the DMX 
IN connector. In RECORD READY and RECORD this signal is 
looped through to the DMX OUT connector without 
termination. In all other states the input signal is terminated. 
 

Play 
 

Starts playing the show, indicated by illuminating the LED in 
the PLAY button. At the end, the unit comes in STOP. 
 
 

Stop 
 

Using this button the first time in RECORD status puts the unit 
in PAUSE, a second push in STOP. In PLAY and LOOP the 

Содержание miniSTORE

Страница 1: ...miniSTORE 512 channel DMX recorder playback Users Manual Software version 2 0 ...

Страница 2: ...n the back panel there are 4 dip switches with the following preset functions Dipswitch 1 and 2 are used for setting number of channels and the framerate 1 2 Frames sec 40 33 25 12 A show with 12 moving lights with constant fading on 16 bit pan tilt CMY and dimmer will record up to 6 minutes 40fps A show with just a few changes might record up to hours Dipswitch 3 and 4 are used for setting the mo...

Страница 3: ...will give a RECORD PAUSE condition indicated by an illuminated RECORD led and a blinking STOP led From here on one can go on with recording via RECORD again waiting for a DMX change or depressing RECORD again or stop by pressing STOP for the second time The DMX signal to be recorded has to be applied to the DMX IN connector In RECORD READY and RECORD this signal is looped through to the DMX OUT co...

Страница 4: ...Control by external contact closure Instead of using the buttons at the front the miniSTORE can also be put into PLAY by an external contact This setting can be made via the dip switches 3 to and 4 to In this mode the front panel controls are inactive so only change over to this mode in a STOP status An external switch has to be connected to the DMX IN XLR between pins 2 and 1 or 3 and 1 Closing t...

Страница 5: ...nal 3 pin Termination 120 Ohm in all modes except RECORD and RECORD READY when the input is looped through to DMX OUT External switch momentary contact from DMX IN pin 2 or 3 to GND pin 1 Memory 512kB static RAM with battery power Battery NiMH battery 70 mAh with trickle charge Hold time 120 days Power supply 115 230 Volt AC 3VA Changing the voltage is internal on the PCB No fuses protection is do...

Страница 6: ...y ELC lighting Support contact support elclighting com Distributed by Worldwide distribution ANIMA LIGHTING LTD Stand 20 CH 1897 Le Bouveret Switzerland T Cell 0041 79 2104613 F 0041 86079 2104613 Email sales elclighting com URL www elclighting com ...