background image

 

dual HTP 

 like single, but merge two DMX universes (primary and 

secondary) in highest take precedence. 

 

dual LTP 

 like dual LTP, like dual HTP but in latest takes 

precedence (on a channel by channel basis) 

 

DMX port as input 

 
When a port is set up as a DMX input, it can be operation in the following 
modes. 

 

disabled 

 the DMX input does nothing 

 

normal 

 any valid DMX is sent onto the network (and internal use) 

using the selected universe (ArtNet) 

 

backup 

 the DMX input will not send data if the selected universe 

is present on the network. If the selected universe is not present on 
the network for several seconds and the input has valid DMX, then it 
will send DMX data. If another sender starts sending the same 
universe, the input will go back input backup mode. 

 
Please note. DMX input 9 and 10 are always fixed to work as input. 
 

Set ID 

 

 
Used the encoder to change the current selected digit, and press the 
encoder to select the next digit. The digits are in hexadecimal (16 
possibilities 0-9, A-F). This means you can have upto 4095 different ID’s in 
the system (ID 000 means that the ID is not used ---). 
 
Press A to store 
Press B to disable (---) 
Press 

 to cancel the operation 

 

Содержание dmXLAN node8

Страница 1: ...dmXLAN node8 10 port DMX Ethernet node Users Manual Software version 1 0 ...

Страница 2: ...9 To connect the RS 232 port to a PC you ll need a 1 to 1 male female sub d 9pin cable NO null modem cross cable Contact Closure Inputs bottom SUB D 9pin Pin Description 1 Ground Shield 2 Input 1 3 Input 2 4 Input 3 5 Input 4 6 9 Ground This inputs have an internal pull up resistor A simple switch can be connected between the input pin and a ground pin The contact inputs can be used to temporarily...

Страница 3: ...rnal terminator resistor and are RDM prepared DMX port 9 and 10 Pin Description 1 Ground Screen 2 Data 3 Data 4 5 DMX ports 9 and 10 are fixed DMX inputs and have a fixed internal terminator There are 2 versions of node8 available the normal and the Full Isolated FI The full isolated version has an optical galvanic isolation barrier up to 1500V This product may only be used for controlling dimmers...

Страница 4: ...can be downloaded from www elclighting com Control through front panel Main Display A Select config menu to recall 1 of 4 previously saved configurations patches B no function Setup Enter setup menu Encoder Select information displays Information displays DMX port status x port does not receive data or DMX when input v port receives data or DMX when input ID setting IP address Version and serial n...

Страница 5: ... the current selected option and press the encoder to select the next option Press A to store the configuration Press B to set the DMX port to it s default value Press to cancel any changes DMX port as output When a port is set up as a DMX output then you can select the working mode of that port Modes are disabled the DMX output is disabled outzero the DMX sends out a DMX test signal with all chan...

Страница 6: ...a if the selected universe is present on the network If the selected universe is not present on the network for several seconds and the input has valid DMX then it will send DMX data If another sender starts sending the same universe the input will go back input backup mode Please note DMX input 9 and 10 are always fixed to work as input Set ID Used the encoder to change the current selected digit...

Страница 7: ... the encoder to change the current parameter and press to select the next Press A to store the configuration Press B to select the factory default IP address and netmask Press to cancel the operation Configuration Menu From the main display press A config Now you can either recall a previous setup or store the current one in one of the 4 options Use the encoder to select a setup Press A to load th...

Страница 8: ...General Information CE Product The dmXLAN node8 permits to the CE requirements set up by the European Community This can be recognized by this label on the outside of the product Technical Specifications Power 85 264 VAC 47 440 Hz 10VA max Dimensions 19 1HE rack unit 483 x 44 x 150 mm Weight 2kg ...

Страница 9: ... ELC lighting Support contact support elclighting com Distributed by Worldwide distribution ANIMA lighting Ltd Route du Stand 20 CH 1897 Le Bouveret Switzerland T 41 79 210 4613 F 4186 079 210 4613 Email sales elclighting com URL www elclighting com ...

Отзывы: