The Rate option can be used to set the rate of the dmXLAN node6x to either; 

 

Sync   

 the DMX output is synchronized to the universe data on the 

network. This is the fastest (lowest latency) setting. 
Note: some equipment might not cooperate with this setting very well. 

 

Fixed rate 

 use this setting if the sync mode doesn't work (40/33/25 fps) 

 

Safe mode 

 this mode has a long break and Mark After Break 

 to be used 

if none of the above mentioned settings work 

The Hold option means that the DMX port will keep sending out the last received 
data on the network for as long as it does not receive new data from the network. 
The default for 

this option is ‘A

lways

. This setting can be changed to time out after a 

chosen time interval. 
 

DMX port as input 

 

 

 
When a port is set up as a DMX input it can operate in the following modes; 

 

disabled 

 the DMX input does nothing 

 

normal 

 any valid DMX is sent onto the network (and internal use) 

using the selected universe (Art-Net) 

 

backup 

 the DMX input will not send data if the selected universe is 

present on the network. If the selected universe is not present on the network 
for several seconds and the input has valid DMX, then it will send DMX data. 
If another sender starts sending the same universe, the input will go back into 
backup mode. 

 

Set ID 

 

 

 
If the node3 is being controlled by the dmXLAN software, an ID can be assigned to the 
unit. The ID can be useful for preprogramming of the network. 

Use the encoder in “Select” and “Edit” mode to change the 3 digits of the ID

. The 

digits are in hexadecimal format (16 possibilities 0-9, A-F). This means you can have 
up 

to 4095 different ID’s in the

 system (ID 000 means that the ID is not used ---). 

Содержание dmXLAN node6x

Страница 1: ...dmXLAN node6x User Manual ...

Страница 2: ...__________________________________________________________________________________ ELC dmXLAN node6x User Manual ...

Страница 3: ...DMX ports DLN6X FI Both versions can be ordered with optional Power over Ethernet for the three Ethernet sockets on the front panel The ELC dmXLAN node6x is available in the following variations DLN6X DLN6X_FI fully isolated DLN6XPOE Power over Ethernet DLN6XPOE_FI Power over Ethernet fully isolated 6 bi directional DMX ports on the front panel XLR RDM compatible Supports sACN Art Net Shownet Inte...

Страница 4: ... Description 1 Ground screen 2 Data 3 Data 4 5 All DMX ports are bi directional can act as input or output with RDM preparation and can optionally be supplied in a fully isolated FI version The ports also have internal 120 Ohm terminator resistors and line biasing for RDM This product may only be used for controlling dimmers and moving lights Using the product outside of these specifications will ...

Страница 5: ... ELC website at www elclighting com The front panel control options will be explained below Main display Encoder Change the view on the display to see the device ID IP address status software version etc Press Encoder Enter the setup menu Setup menu Encoder Select one of the setup items Exit Setup View DMX DMX port 1 DMX port 2 DMX port 3 DMX port 4 DMX port 5 DMX port 6 Set ID Network Options Bac...

Страница 6: ...Select one of the ports to view Back go back to the setup menu Select the view mode press encoder when on Mode and change it to the desired setting and press the encoder again Next scroll to the DMX port and press the encoder to view it When viewing use the encoder to change the start channel or press it to go back DMX port menu Select mode Edit mode In select mode Encoder Select different item Pr...

Страница 7: ...used when programmed via dmXLAN software Priority as long as the primary universe is active it will be on the output otherwise the secondary universe is sent on the output Softpatch setting used when programmed via dmXLAN software Flexpatch setting used when programmed via dmXLAN software The primary and secondary universes can be set to either Art Net or sACN streaming ACN both draft R2 and relea...

Страница 8: ...changed to time out after a chosen time interval DMX port as input When a port is set up as a DMX input it can operate in the following modes disabled the DMX input does nothing normal any valid DMX is sent onto the network and internal use using the selected universe Art Net backup the DMX input will not send data if the selected universe is present on the network If the selected universe is not ...

Страница 9: ...rnet 255 0 0 0 255 255 0 0 255 255 255 0 or select Set to Default For normal Art Net operation the netmask should be set to 255 0 0 0 and the IP address should be between 2 0 0 1 and 2 254 254 254 Backlight The backlight can be set to always be on or to time out after a chosen time interval Factory defaults Restore the settings of the node6x to the default values Power 100 240 VAC 47 440 Hz 10VA m...

Страница 10: ...pparatus including amplifiers that produce heat Unplug this apparatus during lightning storms or when unused for long periods of time Do not place the unit on unstable surfaces Do not place any objects on the power cord Protect it from being walked on or pinched particularly at the plugs and the point where they exit from the device If the power cord or the mains plug is damaged let a qualified te...

Страница 11: ...uilateral triangle is intended to alert the user to the presence of important operating and maintenance servicing instructions in the literature accompanying the product The lightning flash with arrowhead symbol within an equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitu...

Страница 12: ... Which refer to this declaration are manufactured in the Netherlands and complies with the following product specifications and harmonized standards Safety LVD Low Voltage Directive 2014 35 EU EN62368 1 EMC 2014 30 EG EN55032 ROHS II 2011 65 EU With the presumption that the equipment is used and connected according to the manual supplied with the equipment All signal input and output connections m...

Отзывы: