background image

 

 

14 

Users list 

 

 

Figure 2: List of users 

System password: 

In  order  to  ensure  the system  safety,  the  device  prompts  the  operator  to  enter  a  four-digit  password  to  be  able  to  send  SMS 
commands.  The  default  password  is  made  up  of  four  zeroes  (0000).    Please  refer  to  the  SMS  commands  section  to  get  an 
overview of all available commands. 

Enabled users: 

This list contains the phone numbers of users (up to eight) authorized to receive alarm messages and SMS notifications. 

 

   

 

Содержание 539109270

Страница 1: ...V102 20 10 2020 User s manual SMSB242 SMSB482 SMS Switch Butler...

Страница 2: ...mmands section to get an overview of all available commands 14 Enabled users 14 This list contains the phone numbers of users up to eight authorized to receive alarm messages and SMS notifications 14...

Страница 3: ...riodic status message 19 SMS commands 20 Special commands 20 Stop sequential mode 20 Activation without reply 20 Preventing the sending of the signal strength 20 Software requirements 21 Technical dat...

Страница 4: ...ply new functionality or new instructions for products already sold The manufac turer cannot be held liable for loss or damage direct or indirect which may result from use of the product The product i...

Страница 5: ...roni cally and physically including photocopies or saving are only permitted to the user for personal use and prohibited in all other cases without special written authorization The use copying modifi...

Страница 6: ...solar radiation No devices which radiate heat No objects which generate a strong electromagnetic field No corrosive liquids or chemical substances The SMSB242 SMSB482 was designed for operation at tem...

Страница 7: ...7 Use the same voltage level for all relays With high voltage circuits only the phase conductor may be connected via the re lay contacts...

Страница 8: ...gue inputs common earth 9 Code switch for analogue inputs 30 4 59 mm 61 70 mm 45 40 mm 35 42 mm Mo TuWeThFrSaSu IN8 IN4 GSM GPRS IN1 IN2 IN3 IN5 IN6 IN7 RE1 RE2 RE3 RE4 AN1 AN2 SMSB482 I O 2 1 7 6 8 5...

Страница 9: ...NPUTS 12 24V 1000mA NC COM NO NC COM NO NC COM NO NC COM NO RELAY 1 RELAY 2 RELAY 3 RELAY 4 SW1 SW2 SW3 SW4 SW5 SW6 SW7 SW8 LOAD1 LOAD2 LOAD3 LOAD4 For each relay the output maximum current is 5A Tota...

Страница 10: ...losed contacts The device is password protected and can store and manage up to eight users In order to simplify installation and operation of the device the SMSB242 SMSB482 is equipped with a large in...

Страница 11: ...The installation software of the SMSB242 SMSB482 is stored in the Micro SD mass storage In order to start the butler in MSD mode and install the software you must proceed as follows 1 Switch off the...

Страница 12: ...Date time The system date can be updated in this screen the system date is synchronized with the operating system Windows Date and time are only used for the datalogger function Switch The relays are...

Страница 13: ...l damages caused including negligence arising out of or in connection with the use or the inability to use the product The user has been advised by Elbro of the possibility of such damages Neither Elb...

Страница 14: ...ter a four digit password to be able to send SMS commands The default password is made up of four zeroes 0000 Please refer to the SMS commands section to get an overview of all available commands Enab...

Страница 15: ...rs who can work in case of failure It allows sending sequentially the digital input alarming messages observing the order found on the list of users with a time in terval default 5 minutes that can be...

Страница 16: ...correctly set the dip switch considering the chosen sensor Type of sensor Selection of the type of the sensor probe for example PT100 or PT1000 Conversion table In this table all desired values can b...

Страница 17: ...h a customizable text message On this mask the message text for each relay can be individually configured Response message The relay can only be controlled by SMS commands If you send a command to swi...

Страница 18: ...tivating at the same time the system it is connected to This function can be set through the following modes Exchange simple relay exchange is done ON OFF Pulse a programmable pulse of 1 up to 65535 s...

Страница 19: ...form this function the device is equipped with two super capacitors they require at least 30 minutes charging before any SMS can be sent The charge status can be viewed as a percentage in the System S...

Страница 20: ...relay outputs from 1 to 4 0000 R1 1 PW query on current status 0000 PW R 1 4 T 1 255 generates a pulse from 1 to 255 seconds of the se lected relay 0000 R1 T 5 Special commands Stop sequential mode S...

Страница 21: ...load applicable to the device 10A Inputs SMSB242 4 p free contact digital inputs SMSB482 8 potential free contact digital inputs 2 analogue inputs 0 10V 0 20mA PT100 PT1000 General specifications Cont...

Отзывы: