Elbro AG 980 255 909 Скачать руководство пользователя страница 3

 

Detector 3000 

Seite 2 / 11 

Stand: 29.8.19 GB 

 

 

Content

 

1. Introduction / Product Package 

2. Safety Measures 

3. Danger of electric shock and other dangers  

4. Intended Use 

5. Testers Information  

6. Preparation for tests 

 

6.1 Auto-power on/ switching on 

 

6.2 Auto-power off 

7. Conducting Tests  

 7.1. Voltage test 

  

  7.1.1. Low Voltage mode 

 

7.2. Current Test 

7.3. Single-pole phase test  

  

7.4. Phase rotation test  

  

7.5. Continuity test  

  

7.6. Diode test  

  

7.7. Resistance test  

  

7.8. Frequency test  

  

7.9. NCV Test  

  

7.10. Torch light  

  

7.11. Self test  

  

7.12. HOLD Function  

  

7.13. Backlight  

8. Battery Replacement  

9. Technical Data 

10. Cleaning and storage 

 

 

References marked on tester or in instruction manual: 

 

 

Warning of a potential danger, comply with instruction manual. 

 

  Reference. Please pay utmost attention. 

 

  Caution! Dangerous voltage. Danger of electrical shock. 

 

  Continuous double or reinforced insulation complies with category II DIN EN 61140. 

 

  Conformity symbol, the instrument complies with the valid directives. It complies with the 

EMV -Directive (2014/30/EU), Standard EN 61326-1 are fulfilled. It also complies with the Low 

Voltage Directive (2014/35/EU), Standard EN61243-3:2014 is fulfilled. 

 

  Tester complies with the standard (2012/19/EU) WEEE 

 

  The instruction manual contains information and references, necessary for safe operation 

and maintenance of the tester. 

Prior to using the tester (commissioning/ assembly) the user is kindly requested to thoroughly read 

the instruction manual and comply with it in all sections. 

 

Содержание 980 255 909

Страница 1: ...Detector 3000 Seite 0 11 Stand 29 8 19 GB CAT III 1000V CAT IV 600V EN 61326 1 IEC 61243 3 2014 EN Manual DETECtOR 3000 universaltester lectrotesteur elettrotester electrical tester...

Страница 2: ...9 8 19 GB 1 Opening for current measurement 2 Test leads on back side 3 LED display 4 LCD display 5 On off and function button 6 Torchlight and hold button 7 Battery compartment 8 Sensor for cable bre...

Страница 3: ...or in instruction manual Warning of a potential danger comply with instruction manual Reference Please pay utmost attention Caution Dangerous voltage Danger of electrical shock Continuous double or re...

Страница 4: ...e and reliable working It complies with the standard for two pole voltage testers EN61243 3 2014 The Detector 3000 is characterized by the following features Designed to meet international safety stan...

Страница 5: ...cted to be disconnected of the installation it is highly recommended confirming by another means e g use of an adequate voltage tester visual check of the disconnecting point of the electric circuit e...

Страница 6: ...g transport leaking batteries The tester complies with all EMC regulations Nevertheless it can happen in rare cases that electric devices are disturbed by the electrical field of the tester or the tes...

Страница 7: ...for tests 6 1 Auto power on switching on The tester switches on when it detects shorten tips or an AC or DC voltage above approx 6V or a live phase on L2 single pole test It can be switched on with a...

Страница 8: ...n center of the opening at the height of the markings left and right Make sure that only double insulated cables are measured Store test probes safely to avoid any unintended connection Tester switch...

Страница 9: ...y LED lights up buzzer sounds continuously and Con symbol on LCD is on if L1 tip is connected on Anode of diode and L2 tip on Cathode Continuity indication will be off if L1 tip is connected on Cathod...

Страница 10: ...s before shortening tips 7 12 HOLD Function Long press 2 seconds on torchlight function button activates HOLD function and freezes display value With short press on torchlight function button freezing...

Страница 11: ...40 70Hz Safety current Is 3 5mA at 1000VAC Measurement Duty 30s ON operation time 690V 10s ON operation time 690V 240s OFF recovery time Internal battery consumption Approx 120mA Single pole phase tes...

Страница 12: ...est points before cleaning Use a lightly damp cloth with neutral detergent for cleaning the instrument Do not use abrasives or solvents Do not expose the instrument to direct sun light high temperatur...