Trouble shooting

7

Before asking for service, check the following first.

Normal
Performance
inspection

Noise is heard

Phenomenon

Cause or check points

The system does not restart

immediately.

Smells are generated.

Mist or steam are blown out.

Multiple

check

Poor cooling

Application temp. range of air conditioner -7

o

C~43

o

C.

When unit is stopped, it won't restart 

elapsed to protect the system.

When the electric plug is pulled out 

and reinserted, the protection circuit 

During unit operation or at stop, 

a swishing or gurgling noise may 

(This noise is generated by

refrigerant flowing in the system.)

During unit operation, a cracking

noise may be heard.This noise is 

temperature changes.

Should there be a big noise from

 filter may be too dirty.
This is because the system 

circulates smells from the interior

During COOL or DRY operation, 

This is due to the sudden cooling

Is power plug inserted?

Is there a power failure?

Is fuse blownout?

Is the air filter dirty?

Are there any obstacles before 

Is temperature set correctly?

Are there some doors or 

Is there any direct sunlight

through the window during the 

Are there too much heat sources

or too many people in the room 

In dry mode, fan 

speed can’t be changed.

In DRY mode, when room 

than temp.2

o

C,unit will 

regardless of FAN setting.

Maximum: D.B

10.The appliance must be installed on a strong enough support.

9.Young children should be supervised ensure that they do not

play with the appliance.

8.The appliance is not intended to use by young children or infirm

persons without supervision.

7.The used batteries should be disposed of properly.

6.

After installation, the power plug should be easily reached..

5.The wiring method should be in line with the local wiring standard.

4.The distance between the indoor unit and the floor should be

more than 2m.

3. If the fuse on PC board is broken please change it with a fuse

type T. 3.15A/250V.

11.The wiring diagram is attached inside the machine.

2. If the supply cord is damaged, it must be replaced by the

manufacturer or its service agent or a similar qualified person.

The type of connecting wire is H05RN-F or H07RN-F

Cautions

The machine is adaptive in following situation

1.Applicable ambient temperature range:

Cooling

Heating

Indoor

Outdoor

Outdoor

Indoor

Maximum: D.B / W.B 32

o

C/23

o

C

18

o

C/14

o

C

43

o

C/26

o

C

18

o

C

27

o

C

15

o

C

24

o

C/18

o

C

-7

o

C/-8

o

C

Minimum:  D.B / W.B

Minimum:  D.B

Maximum: D.B

Minimum:  D.B

Maximum: D.B / W.B

Minimum:  D.B / W.B

For:  T1

during cooling operation?

cooling operation?(Use curtain)

 windows left open?

 inlet and outlet?

Normally it should be cleaned 

every 15 days.

run intermittently at LOW speed 

temperature becomeslower 

indoor unit may blow out mist.

of indoor air.

air such as the smell of furniture,

paint, cigarettes.

air flow in unit operation, air 

generated by the casing expanding

or shrinking because of

be heard.At first 2-3 minutes after

unit start, this noise is more noticeable. 

will work for 3 minutes to protect the

air conditioner.

immediately until 3 minutes have

If the fuse of outdoor unit on PC board is broken, please change

it with the type of T. 25A/250V.

Application t

em

p. range of air conditioner -7

o

C~52

o

C.

T1:

T3:

For:  T3

Cooling

Heating

Indoor

Outdoor

Indoor

Outdoor

Maximum: D.B / W.B

Minimum: D.B / W.B
Maximum: D.B / W.B

Minimum: D.B
Maximum: D.B

Minimum: D.B
Maximum: D.B / W.B

Minimum: D.B / W.B

32

o

C/23

o

C

18

o

C/14

o

C

52

o

C/31

o

C

18

o

C

27

o

C

15

o

C

24

o

C/18

o

C

-7

o

C/-8

o

C

Trouble shooting

Содержание ELBA12HAN20

Страница 1: ...anual for future reference SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL 0011515693 ANCE TROUBLE SHOOTING 6 7 1 2 5 Contents PARTS AND FUNCTIONS OPERATION MAINTEN CAUTIONS TROUBLE SHOOTING ELBA12LA...

Страница 2: ...is detailed in installation manual The cord of the H05RN F or H07RN F type must be used for power connection and interconnection between outdoor unit and indoor unit Instructions on charging of refrig...

Страница 3: ...IBITION Do not channel the air flow directly at people especially at infants or the aged Do not try to repair or reconstruct by yourself Do not insert objects into the air inlet or outlet PROHIBITION...

Страница 4: ...10 12 SWING LEFT RIGHT button 13 15 SLEEP button 14 HEALTH button 16 18 POWER ON OFF button 20 TEMP button 21 TIME OFF ON 22 1 Mode display 1 2 3 4 5 9 10 11 12 13 14 15 16 17 8 22 23 24 25 19 20 21...

Страница 5: ...3 Pos 4 Pos 5 Pos 6 For each press of button remote controller displays as follows remote controller Cautions Pos 2 No initial state disaplayed on remote controller the vertical flap will be fixed on...

Страница 6: ...ther The unit will run for further 6 hours then stops Temp is higher than temp setting so that room temperature won t be too low for your sleep O C 1O C Press button the remote controller will show an...

Страница 7: ...ng should be reset According to the Time setting sequence of TIME ON or Press the button for each time setting time in the first 12 hours increased by 0 5 hour every time after 12 hours increased by 1...

Страница 8: ...rious stains use a neutral detergent diluted with water Wring the water out of the cloth before wiping then wipe off the detergent completely Indoor Body Once every two weeks 1 Open the lnlet Grille 2...

Страница 9: ...the power plug should be easily reached 5 The wiring method should be in line with the local wiring standard 4 The distance between the indoor unit and the floor should be more than 2m 3 If the fuse o...

Страница 10: ......

Страница 11: ......

Страница 12: ...W B 32 23 D B W B 18 14 D B 43 26 D B 18 D B 27 D B 15 D B W B 24 18 D B W B 7 8 2 D B W B 32 23 D B W B 18 14 D B W B 52 13 D B 18 D B 27 D B 15 D B W B 24 18 D B W B 7 8 2 H05RN F H07RN F 3 T 3 15...

Страница 13: ...40 104 OFF 1 4 2 5 6 3 6...

Страница 14: ...1 2 ON 0 5 10 OFF 0 5 10 ON OFF 3 12 0 5 12 1 4 ON OFF 5 HEALTH HEALTH HEALTH TURBO TURBO 1 2 R 03 3 4 7 5...

Страница 15: ...1 1 1 o 1 1 o 6 2 1 2 o 1 2 o 3 1 o 3 3 4 4 5 8 3 3 1 2 3 1 2 3...

Страница 16: ...1 TURBO HEALTH SLEEP EXTRA FUNCTION TIME OFF TIME ON SWING 1 2 3 3 4 1 ON OFF 2 1 1 3 FAN AUTO COOL DRY 2 HEAT FAN Pi 23 26 No AUTO COOL 16 Pi 1 2 2 3 A B...

Страница 17: ...4 5 9 10 11 12 13 14 15 16 17 8 22 23 24 25 19 20 21 18 7 6 HEALTH SLEEP EXTRA FUNCTION TIME OFF TIME ON SWING TURBO HEAT 2 3 1 1 AUTO COOL DRY FAN 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 LED 18 19 2...

Страница 18: ...1 OFF...

Страница 19: ...ELB F NR70H F NR50H F VV50H K 24 K 18 12K...

Страница 20: ...1 2 5 6 7 0011515693 ELBA12LAN20 ELBA12HAN20 ELBA18LAN20 ELBA18HAN20 ELBA24LAN20 ELBA24HAN20 ELBA30LAN20 ELBA30HAN20...

Отзывы: