38
IMPORTANT
All intervention regarding installation and maintenance of the appliance must be
fulfilled with original factory parts.
The manufacturer declines any liability resulting from the non-compliance of this
obligation.
AIR VENT NECESSARY FOR GAS COMBUSTION = (2 m
3
/h x kW)
BURNERS
Air necessary for combustion [m
3
/h]
Oven
9,40
Grill
6,00
GAS MAINTENANCE
TABLE FOR THE CHOICE OF THE INJECTORS
BURNERS
Nominal
power
[kW]
Reduced
power
[kW]
LPG
G30 (50 mbar)
Ø injector
[1/100 mm]
Ring opening [mm]
Oven
4,70
1,30
92
1 (*)
Grill
3,00
1,50
75
2 (*)
(*) = Reference value