PacDrive™ M
field bus PROFIBUS-DP
page 49
6.4 PROFIBUS-DP Slave
Ko
rr
ek
tu
ra
us
dr
uc
k
IEC start address of the Profibus output data of this slave. The IEC
output data range set here must not overlap with the ranges of
other modules (e.g. with the range of a PROFIBUS DP master
module).
Input address:
IEC start address of the Profibus input data of this slave. The IEC
input data range set here must not overlap with the ranges of other
modules (e.g. with the range of a PROFIBUS DP master module).
Diagnosis address:
The diagnosis address is not supported.
Identification
Station address:
Profibus address of the slave within the Profibus data traffic.
Station name:
Any text can be entered here.