field bus PROFIBUS-DP
PacDrive™ M
6 Configuration, Parametrization
Ko
rr
ek
tu
ra
us
dr
uc
k
ErrorCode
Error codes for BadDeviceAdr 0-125, i.e. for the corresponding
Profibus slave
Table 6-3: PROFIBUS-DP master / Parameter ErrorCode 1
Error codes for BadDeviceAdr 255, i.e. for Profibus master
err_
event
Signification
error
Source
Help
2
station reports overflow
master
telegram
check length of configured
slave configuration or
parameter data
3
request function of master
is not activated in the
station
master
telegram
check slave if
PROFIBUS_DP norm
compatible
9
no answer-data, although
the slave must response
with data
slave
check configuration data of
the station and compare it
with the physical I/O data
length
17
no response of the station
slave
check bus cable, check bus
address of slave
18
master not into the logical
token ring
DEVICE
check FDL-Address of
master or highest-station-
Address of other master
systems. examine bus
cabling to bus short circuits
21
faulty parameter in request
master
telegram
contact hotline
err_
event
signification
error
source
help
0
no mistakes appear
50
USR_INTF-Task not found
DEVICE
contact
technical support
51
no global data-field
DEVICE
contact
technical support
52
FDL-Task not found
DEVICE
contact
technical support
53
PLC-Task not found
DEVICE
contact
technical support
54
non existing master parameters
DEVICE
execute download of
data base again
55
faulty parameter-value in the
master parameters
project
planning
contact
technical support