background image

                                                                                            -        -                                                                XM605-V1.0-NR 

 

 

 

 

 
 
 
DMX-512 connection with DMX terminator 

For installations where the DMX cable has to run a long distance or is in an electrically noisy environment, 
such as in a discotheque, it is recommended to use a DMX terminator. This helps in preventing corruption of 
the digital control signal by electrical noise. The DMX terminator is simply an XLR plug with a 120 

Ω

 resistor 

connected between pins 2 and 3,which is then plugged into the output XLR socket of the last fixture in the 
chain. Please see illustrations below. 

 

 

 
Projector DMX start address selection 

All fixtures should be given a DMX starting address when using a DMX signal, so that the correct fixture 
responds to the correct control signals. This digital starting address is the channel number from which the 
fixture starts to “listen” to the digital control information sent out from the DMX controller. The allocation of 
this starting address is achieved by setting the correct number on the display located on the base of the device. 
You can set the same starting address for all fixtures or a group of fixtures, or make different address for each 
fixture individually. 
If you set the same address, all the units will start to “listen” to the same control signal from the same channel 
number. In other words, changing the settings of one channel will affect all the fixtures simultaneously. 
If you set a different address, each unit will start to “listen” to the channel number you have set, based on the 
quantity of control channels of the unit. That means changing the settings of one channel will affect only the 
selected fixture. 
 
In the case of the move head, which is a 2 channel fixture, you should set the starting address of the first unit to 
1, the second unit to 3 (2 + 1), the third to 5 (2 + 3), and so on. 

 

Address 1                                            Address 3                                      Address5 

 

Содержание WW TONE

Страница 1: ...WW TONE Elation Professional 6122 S Eastern Ave Los Angeles Ca 90040 www elationlighting com ...

Страница 2: ... instructions of this manual INTRODUCTION Thank you for having chosen this professional LED moving head You will see you have acquired a powerful and versatile device Unpack the device Inside the box you should find 1 One XLR connection cable 2 A power cable 3 One safety rope 4 Manual 5 Barn door 6 Frost filter Please check carefully that there is no damage caused by transportation Should there be...

Страница 3: ...the device has been exposed to temperature changes due to environmental changes do not switch it on immediately The arising condensation could damage the device Leave the device switched off until it has reached room temperature This device falls under protection class I Therefore it is essential that the device be earthed The electric connection must carry out by qualified person Make sure that t...

Страница 4: ...is a lighting effect for professional use on stages in discotheques theatres etc the device was designed for indoor use only This fixture is only allowed to be operated with the max alternating current which stated in the technical specifications in the last page of this manual Lighting effects are not designed for permanent operation Consistent operation breaks may ensure that the device will ser...

Страница 5: ...ecured with a secondary safety attachment e g an appropriate safety rope Never stand directly below the device when mounting removing or servicing the fixture The operator has to make sure the safety relating and machine technical installations are approved by an expert before taking the device into operation for the first time These installations have to be approved by a skilled person once a yea...

Страница 6: ...s on the bottom of the base and over the trussing system or a safe fixation spot Insert the end in the carabine and tighten the safety screw Notice this step is quite important to ensure that the fixture will not drop out by the damage of the clamp DMX 512 control connection Connect the provided XLR cable to the female 3 pin XLR output of your controller and the other side to the male 3 pin XLR in...

Страница 7: ... listen to the digital control information sent out from the DMX controller The allocation of this starting address is achieved by setting the correct number on the display located on the base of the device You can set the same starting address for all fixtures or a group of fixtures or make different address for each fixture individually If you set the same address all the units will start to lis...

Страница 8: ...n the control panel which could be used to set the address turn ON OFF operating the program and reset Mode Esc press this key to enter into edit mode Press this key under the edit mode if you want to return to previous menu it will exit from edit mode 60 seconds after the last keypress UP screen will flash when pressing this key in normal mode the adress value will increasing Keep pressing this k...

Страница 9: ... is no DMX DFSE ON OFF Default setting POHO ON OFF Power on to preserve the MANL settings FANS AUTO HIGH LOW Fan s mode select VER V 1 0 V 9 9 Software version MANL WHIT STRB WXXX SXXX Manual adjust intensity Manual adjust intensity TIME LIFE 0000 9999 HOURS Life time of machina running CODE CXXX Passord of clear time 038 CLFE ON OFF Clear machina running time EDIT STEP S 01 S 48 Select steps of p...

Страница 10: ...U Display the DMX 512 value of each channel With this function you can display the DMX 512 value of each channel The display will automatically detail the changing DMX values as they are received from the controller SLAV Slave setting for Master Slave Operation With this function you can define the device as slave for operation in Master Slave mode Each slave setting will have a different function...

Страница 11: ...is off by default FLIP This function will flip the display readout by 180 allowing for better visualization when the fixture is mounted in an inverted position D ON The display is designed to turn off during normal operation to avoid excessive light in situations that require an extremely dark environment This function will adjust the time delay the fixture will remain on before it turns off This ...

Страница 12: ...l manual settings will be lost once the fixture is tuned off This function is used to change the functionality of the internal cooling fans Follow the procedure below to access the fan menu 1 Access the main menu 2 Tap the UP or DOWN button until SPEC is displayed press ENTER 3 Tap the UP or DOWN button until FANS is displayed press ENTER 4 The display will show HIGH AUTO LOW 5 Press UP or DOWN bu...

Страница 13: ...run time from being erased accidently The access code is 038 CLFE Clear Fixture Run Time This function resets the run time to zero Edit Internal Program Settings The fixture comes equipped with a built in DMX recorder that allows custom programs to be installed and recalled directly from the fixture s control board Programs can be created and stored using the fixture s control board or by using an...

Страница 14: ...nnel that is being edited It will be displayed as 11XX it stands for Channel 11 of the editing scene the DMX value is XX 6 Adjust the DMX value by tapping the UP button until you get the expected effect for this channel 7 Press ENTER to enter the editing of the other channels of the scene 8 Repeat steps 5 8 until you finish setting all the DMX values for all the channels of this scene each scene c...

Страница 15: ...OWN buttons 3 Press MODE ESC the display shows SC01 4 Press MODE ESC the display shows C 01 5 Select CEDT by pressing the UP or DOWN buttons 6 Press MODE ESC the display shows OFF 7 Press UP the display will read ON 8 Press MODE ESC the display shows SC02 You successfully downloaded the first scene 9 Adjust the Step time as described above 10 Call up the second scene in your controller now 11 Repe...

Страница 16: ...slow to fast 224 255 Led turn on Instructions for installing the barn door and frost filter For this device the barn door and the frost filter can be installed separately or together 1 When only install the frost filter use the rotating clips on the lens cover to fix it 2 When only install the barn door loose the 4 M4 screws on the lens cover put on the bar door and tighten the screws 3 When insta...

Страница 17: ...condition and extend the life time we suggest a regular cleaning to the lights 1 Clean the inside and outside lens each week to avoid the weakness of the lights due to accumulation of dust 2 Clean the fan each week 3 A detailed electric check by approved electrical engineer each three month make sure that the circuit contacts are in good condition prevent the poor contact of circuit from overheati...

Отзывы: