Vision Scan 250™
©Elation Professional® 22 Vision Scan 250™
STEP
S–01 ~S–48
Set the amount of your
program
C–01~C–30
0 1 XX(00~FFH)
3 0 XX(00~FFH)
Edit the channels of each
scene
TIME
T XXX(001~999)
Time for each scene
SCXX
CEDT
ON/OFF
Edit program via controller
REC.
RE.XX
Auto Save
13 EDIT
RUN
ON/OFF
Program test
Main Menu Functions
1. ADDRESS MENU
-
AOO1 - A511
(Value) - This is where you set the fixtures DMX address.
Setting/Changing the DMX Address
After applying power to the
VISION SCAN 250™
the LED will display the fixture’s
current DMX address immediately after the reset sequence. If the fixture is not
receiving a DMX signal the display will flash continuously. To set or adjust a DMX
address, please follow the procedure below:
1. Switch on the
VISION SCAN 250™
and wait for the fixture reset process to
finished.
2. Press the
Mode/Esc
button to access the main menu. Toggle through the menu by
pressing the
Up
and
Down
buttons until the display shows
A001
. Tap the enter
button to make changes to the address, the current three digit address will
immediately begin to flash.
3. While the current three-digit address is flashing, use the
Up
and
Down
buttons
to
select adjust the address. Lock your new address into the unit’s memory by
pressing the
Enter
button. After the new address has been successfully stored into
the fixture’s memory the LED will briefly readout
PASS
.
The DMX address is non-destructible and will remain in the fixture’s memory even when
power to the fixture has been switched off. Memory is backed-up and retained by an
internal power source with a five year shelf life.